UT66002214-05
All copying, even partial, of this manual is strictly forbidden
11
DUCTIMAX
33
34
43
44
Speed
min
med
max
min
med
max
min
med
max
min
med
max
Declared speed
1,6,7
1,6,7
1,4,7
1,4,7
Rated air flow DF 1R
(E)
m³/h
195
357
398
195
357
398
302
524
642
302
524
642
Available static pressure DF 1R
(E)
Pa
19
50
63
19
50
63
17
50
75
17
50
75
Power input DF 1R
(E)
W
34
85
106
34
85
106
76
143
192
76
143
192
Maximum current absorption
A
0,56
0,56
1,10
1,10
Total cooling capacity DF 1R
(1)(E)
kW
1,44
2,26
2,48
1,57
2,67
2,93
1,89
3,13
3,64
2,27
3,73
4,40
Sensible cooling capacity DF 1R
(1)(E)
kW
1,01
1,68
1,84
1,07
1,84
2,01
1,41
2,35
2,78
1,56
2,57
3,04
FCEER class DF 1R
(E)
D
D
E
D
Water flow DF 1R
(2)
l/h
252
402
445
274
473
522
339
562
656
403
664
788
Water pressure drop DF 1R
(2)(E)
kPa
2
5
5
3
7
9
3
8
11
6
13
18
Heating capacity DF 1R
(3)(E)
kW
2,09
3,09
3,29
2,09
3,09
3,29
2,80
3,82
4,24
2,80
3,82
4,24
FCCOP class DF 1R
(E)
C
C
D
D
Water flow DF 1R
(3)
l/h
183
271
288
183
271
288
245
334
371
245
334
371
Water pressure drop DF 1R
(3)(E)
kPa
2
3
4
2
3
4
3
5
6
3
5
6
Total sound power level DF 1R
(4)
dB(A)
36
47
51
36
47
51
38
52
58
38
52
58
Additional coil DF - number of rows
1
1
1
1
Inlet + radiated sound power level DF 1R (4)(E)
dB(A)
37
48
52
37
48
52
36
50
56
36
50
56
Outlet sound power level DF 1R
(4)(E)
dB(A)
36
47
51
36
47
51
35
49
55
35
49
55
Water content - additional coil DF 1R
dm³
0,59
0,59
0,59
0,59
Power supply cable type
N07V-K
Cross-section area of power cables
(5)
mm²
1,00
1,00
1,50
1,50
Safety fuse F
A
1
1
2
2
Fuses type
gG
DUCTIMAX
53
54
63
64
Speed
min
med
max
min
med
max
min
med
max
min
med
max
Declared speed
1,6,7
1,6,7
5,6,7
5,6,7
Rated air flow DF 1R
(E)
m³/h
333
683
755
333
683
755
1050
1163
1289
1050
1163
1289
Available static pressure DF 1R
(E)
Pa
12
50
61
12
50
61
40
50
60
40
50
60
Power input DF 1R
(E)
W
76
167
192
76
167
192
235
280
332
235
280
332
Maximum current absorption
A
1,10
1,10
2,10
2,10
Total cooling capacity DF 1R
(1)(E)
kW
2,22
4,20
4,60
2,44
4,76
5,20
6,15
6,66
7,21
6,91
7,49
8,12
Sensible cooling capacity DF 1R
(1)(E)
kW
1,60
3,07
3,36
1,70
3,31
3,62
4,51
4,88
5,29
4,83
5,23
5,67
FCEER class DF 1R
(E)
D
Water flow DF 1R
(2)
l/h
394
749
822
432
846
925
1095
1191
1295
1225
1333
1448
Water pressure drop DF 1R
(2)(E)
kPa
2
7
8
3
10
12
13
16
18
20
23
26
Heating capacity DF 1R
(3)(E)
kW
3,40
5,17
5,45
3,40
5,17
5,45
6,42
6,73
7,06
6,42
6,73
7,06
FCCOP class DF 1R
(E)
D
Water flow DF 1R
(3)
l/h
297
452
477
297
452
477
562
590
618
562
590
618
Water pressure drop DF 1R
(3)(E)
kPa
6
13
14
6
13
14
19
21
22
19
21
22
Total sound power level DF 1R
(4)
dB(A)
38
55
58
38
55
58
61
63
69
61
63
69
Additional coil DF - number of rows
1
1
1
1
Inlet + radiated sound power level DF 1R (4)(E)
dB(A)
36
53
56
36
53
56
59
61
67
59
61
67
Outlet sound power level DF 1R
(4)(E)
dB(A)
35
52
55
35
52
55
58
60
66
58
60
66
Water content - additional coil DF 1R
dm³
0,97
0,97
0,97
0,97
Power supply cable type
N07V-K
Cross-section area of power cables
(5)
mm²
1,50
1,50
1,50
1,50
Safety fuse F
A
2
2
2
2
Fuses type
gG
(1) Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity) according to EN1397:2015
(2) Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity)
(3) Water temperature 65°C / 55°C, air temperature 20°C
(4) Sound power measured according to standards ISO 3741 and ISO 3742
(5) The shown section is to be considered as the minimum recommended section. The cables must be chosen in compliance with CEI - UNEL 35024/1. standard.
(E) EUROVENT certified data
Power supply 230-1-50 (V-ph-Hz)