DUCTIMAX
TECHNICAL MANUAL
10
DUCTIMAX
53
54
63
64
Speed
min
med
max
min
med
max
min
med
max
min
med
max
Declared speed
1,6,7
1,6,7
5,6,7
5,6,7
Rated air flow
(E)
m³/h
333
687
760
333
687
760
1050
1163
1289
1050
1163
1289
Available static pressure
(E)
Pa
12
50
61
12
50
61
40
50
60
40
50
60
Power input
(E)
W
76
167
192
76
167
192
235
280
332
235
280
332
Maximum current absorption
A
1,10
1,10
2,10
2,10
Total cooling capacity
(1)(E)
kW
2,22
4,22
4,63
2,44
4,79
5,23
6,15
6,66
7,21
6,91
7,49
8,12
Sensible cooling capacity
(1)(E)
kW
1,60
3,09
3,39
1,70
3,33
3,64
4,51
4,88
5,29
4,83
5,23
5,67
FCEER class
(E)
D
Water flow
(2)
l/h
394
753
828
432
850
930
1095
1191
1295
1225
1333
1448
Water pressure drop
(2)(E)
kPa
2
7
8
3
10
12
13
16
18
20
23
26
Heating capacity
(3)(E)
kW
2,54
4,76
5,17
2,63
5,03
5,49
6,68
7,22
7,80
7,18
7,80
8,46
FCCOP class
(E)
D
Water flow
(3)
l/h
442
827
898
457
875
955
1162
1256
1357
1248
1356
1472
Water pressure drop
(3)(E)
kPa
2
7
8
3
9
11
12
14
16
17
20
23
Standard coil - number of rows
3
4
3
4
Total sound power level
(4)
dB(A)
38
55
58
38
55
58
61
63
69
61
63
69
Inlet + radiated sound power level
(4)(E)
dB(A)
36
53
56
36
53
56
59
61
67
59
61
67
Outlet sound power level
(4)(E)
dB(A)
35
52
55
35
52
55
58
60
66
58
60
66
Water content - standard coil
dm³
2,50
3,30
2,50
3,30
Power supply cable type
N07V-K
Cross-section area of power cables
(5)
mm²
1,50
1,50
1,50
1,50
Safety fuse F
A
2
2
2
2
Fuses type
gG
(1) Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity) according to EN1397:2015
(2) Water temperature 7°C / 12°C, air temperature dry bulb 27°C, wet bulb 19°C (47% relative humidity)
(3) Water temperature 45°C / 40°C, air temperature 20°C
(4) Sound power measured according to standards ISO 3741 and ISO 3742
(5) The shown section is to be considered as the minimum recommended section. The cables must be chosen in compliance with CEI - UNEL 35024/1. standard.
(E) EUROVENT certified data
Power supply 230-1-50 (V-ph-Hz)
» 4 pipes
DUCTIMAX
13
14
23
24
Speed
min
med
max
min
med
max
min
med
max
min
med
max
Declared speed
2,5,7
2,5,7
1,5,7
1,5,7
Rated air flow DF 1R
(E)
m³/h
109
243
270
109
243
270
170
272
336
170
272
336
Available static pressure DF 1R
(E)
Pa
10
50
63
10
50
63
19
50
77
19
50
77
Power input DF 1R
(E)
W
24
57
82
24
57
82
34
69
106
34
69
106
Maximum current absorption
A
0,40
0,40
0,56
0,56
Total cooling capacity DF 1R
(1)(E)
kW
0,92
1,70
1,86
0,95
1,88
2,06
1,26
1,88
2,24
1,35
2,09
2,49
Sensible cooling capacity DF 1R
(1)(E)
kW
0,61
1,20
1,31
0,63
1,28
1,40
0,88
1,33
1,57
0,92
1,42
1,70
FCEER class DF 1R
(E)
D
Water flow DF 1R
(2)
l/h
160
302
333
167
334
368
221
335
404
238
370
447
Water pressure drop DF 1R
(2)(E)
kPa
2
5
6
2
7
8
3
6
8
4
8
12
Heating capacity DF 1R
(3)(E)
kW
1,14
1,93
2,06
1,14
1,93
2,06
1,55
2,07
2,32
1,55
2,07
2,32
FCCOP class DF 1R
(E)
C
C
D
D
Water flow DF 1R
(3)
l/h
100
169
180
100
169
180
136
181
204
136
181
204
Water pressure drop DF 1R
(3)(E)
kPa
1
2
3
1
2
3
2
3
3
2
3
3
Total sound power level DF 1R
(4)
dB(A)
28
49
52
28
49
52
39
50
54
39
50
54
Additional coil DF - number of rows
1
1
1
1
Inlet + radiated sound power level DF 1R (4)(E)
dB(A)
26
47
50
26
47
50
37
46
52
37
46
52
Outlet sound power level DF 1R
(4)(E)
dB(A)
25
46
49
25
46
49
36
45
51
36
45
51
Water content - additional coil DF 1R
dm³
0,47
0,47
0,47
0,47
Power supply cable type
N07V-K
Cross-section area of power cables
(5)
mm²
1,00
1,00
1,00
1,00
Safety fuse F
A
1
1
1
1
Fuses type
gG
Summary of Contents for Ductimax