DMC-1660 375
usec
DMC-1670 500
usec
DMC-1680 500
usec
In order to run the DMC-1600 motion controller in fast mode, the fast firmware must be uploaded.
This can be done through the Galil terminal software such as DMCTERM and WSDK. The fast
firmware is included with the controller utilities. In order to set the desired update rates, use the
command TM.
When operating the controller with the fast firmware, some functionality is limited. The following
functions are disabled:
Gearing Mode
Ecam Mode
Pole (PL)
Analog Feedback (AF)
Stepper Motor Operation (MT 2,-2,2.5,-2.5)
Trippoints allowed only in thread 0
DMA channel
Tell Velocity Interrogation Command (TV)
Aux Encoders (TD)
Dual Velocity (DV)
Peak Torque Limit (TK)
Notch Filter (NB, NF, NZ)
Second Field of EI
DMC-1600
Chapter 6 Programming Motion
•
115