2
Gal Pro
Instruction 1.0
Output Checkup
Technically turning on the controller outputs is designed in order to check solenoid connection and
some other elements.
Before entering the output checkup process pause the controller.
Turn the selector to Service Menu.
Move down to Output Test- Press + for Out Test.
Press "+" in order to start the process.
When entering the process the controller scans all of the outputs and then prompts the next screen
in which you can select, via the cursor, the number of output to open. Use the Next and Prev keys
to move the cursor to the different outputs and press Enter to open the output. An additional Enter
will close the output. It is possible to open several outputs together for a predefined time that is
programmed in the Out. Test. Tim-Sc parameter.
Changing the Batteries for Gal Pro DC
The controller detects the battery voltage. This voltage is displayed in the service menu. When the
voltage drops below the required value the controller shows a Low Voltage message.
Detecting too low voltage causes all of the solenoids to close and the controller permanently pauses.
When the controller has a low battery alarm you must replace the battery as soon as possible.
When the controller has a No Voltage alarm do not allow the controller to control the system.
12. Maintenance
Summary of Contents for Gal Pro 4
Page 1: ...GalPro AC DC Operating Manual...
Page 2: ......