2
Gal Pro
Instruction 1.0
Sequence Timing
In this menu enter the timetable for sequence operation.
Subject
Example
Explanation
Sequence No
1
Change the sequence number via the Next and Prev keys.
Time Method
Cyclic.
Via the "+" and "-" keys select one of the options:
Cyclic. - Irrigation according to cycle of days. For example
1=every day, 2=every other day and so on.
Weekly - Irrigation according to selected days of the week.
Cycle Days
1
The number of days of the cycle - see the previous item.
Start Time
08:00
The start time.
Stop Time
0:00
The stop time for cyclic irrigation. At this time the irrigation
stops and all of the remaining cycles are erased.
Cycles in Day
2
The number of cycles to be carried out.
Cycl.Time H:M
5:00
The time between two cycle starts.
Please note: The day of the week will only be displayed if the "time method" is weekly.
Irrigate Sunday
No
Selecting Yes will start the sequence on this day.
Irrigate Monday
No
Selecting Yes will start the sequence on this day.
Irrigat.Tuesday
No
Selecting Yes will start the sequence on this day.
Irrig.Wednesday
No
Selecting Yes will start the sequence on this day.
Irrig. Thursday
No
Selecting Yes will start the sequence on this day.
Irrigate Friday
No
Selecting Yes will start the sequence on this day.
Irrig. Saturday
No
Selecting Yes will start the sequence on this day.
The controller setup is now completed. Move back to System Setup and select System Active. The
controller carries out a short initialization process.
If the controller is programmed to irrigate today and the start time has already passed the controller
will start irrigating immediately.
In the case of multiple sequences one has to consider:
Gal Pro AC can simultaneously open about 4 irrigation valves, main, fertilizer and filter, as opposed
to Gal Pro DC which can open all the outlets simultaneously.
6. Programming
Services
System Setup
Sequence Setup
Filter Flush
Fertilization
Sequence Timing
Valve • Water & Fert.
Water
Counter
Diaries
Alarms
Valve Info
Sequence Info
Manual Overriding
Sequence Status
Valve Status
System Status