Gal Pro
Instruction 1.0
Additional General Information
As previously mentioned, additional general information can
be found in the following different menus: Water Counters,
Fertilization and Filter Flush.
Water Counters
Subject
Example
Explanation
Water counter
No.
1
The water counter to which the parameters are related. Change
the water counter number by the Next and Prev keys.
Curr.Status
Active
The options are:
N.Activ - The water counter is not defined.
Active - The counter is defined properly.
Irrigat - The water counter has a flow rate during irrigation.
LeakFlt - The counter recognizes uncontrolled water.
Not Exe - Pulse timeout has been reached.
Fault
Current Flow
80
The current flow rate in the water counter.
Daily Wtr.-m3
136
The total amount of water that has flowed through the water
counter today.
Accumulat.-m3
2483
The total amount of water irrigated since the last accumulation
reset.
Start Ac.Date
01/04
The date when the last reset took place.
Leakage-m3
0
The amount of uncontrolled water since the last uncontrolled
water reset.
Press + to init
accm
Resets the accumulation in the water counter.
7. Information and Programming Menus
Services
System Setup
Sequence Setup
Filter Flush
Fertilization
Sequence Timing
Valve • Water & Fert.
Water Counter
Diaries
Alarms
Valve Info
Sequence Info
Manual Overriding
Sequence Status
Valve Status
System Status