Gal Pro
Instruction 1.0
Number of outputs in Gal Pro 4: 9 (4 valves, master, fertilizer pump, 2 filters and alarm).
Number of outputs in Gal Pro 8: 13 (8 valves, master, fertilizer pump, 2 filters and alarm).
Number of Inputs: 8 (4 water counters, 1 fertilizer counter, 3 condition inputs).
Analog Inputs: None
Input Voltage Gal Pro DC: 6 volts (4 * 1.5 VDC Alkaline D type batteries installed inside the
controller). Or 12 VDC battery 5 Amp * H or more connected to a charger or solar panel.
Power Consumption When Idle: 0.2 - 0.3 mA.
Type of Solenoids: 12 VDC latch - 2 or 3 wires.
Pulse Duration: 20 mS to 200mS - programmable
Dimensions:
H - 23 cm
L - 30 cm
W - 13 cm
gal pro DC Weight(without Batteries): 1.75 kg
Gal pro AC Weight (without protection cards): 2.95 kg
Irrigation According to: M3, Liters, Seconds, Minutes, Hours
Fertilization According to: Minutes, Liter/M3, calculated proportional including water before
and after.
Filter Flushing: Up to 2 filters according to time, water quantity or PD switch.
Irrigation Day Definition: according to cycle days or days of the week.
Irrigation Cycles per Day: From 1 to 255.
Diaries: Alarm and event records of irrigation activity. Up to 128 events.
Timing of Opening and Closing Valves: Full control of operation order of the master valve and
the irrigation valves at the beginning and end of irrigation. Overlapping the valve operation in
changing valves.
Manual Control: Full manual control of sequences and valves including control of irrigation
outside of the program timetable.
External Conditions: 3 input conditions that enable operating, pausing, starting and stopping the
irrigation according to condition elements with dry contacts.
Alarms: The controller displays all types of alarms during the irrigation and fertilization. It is
possible to define automatic alarm canceling. In addition the alarm output can be connected to a
cellular text message sender.
Saving Data: The controller saves all of the definitions and irrigation programs even when the
power supply is disconnected. The data that are not saved are: time, date and accumulations.
13. Technical Specifications