GAELCO - RING RIDERS
47
When this message is not displayed but the bike does not move, the safety stop circuit
should be tested.
If the red knob is pressed along the play, a warning message is displayed on the screen
indicating how to unlock the knob.
9.9.2 SAFETY STOP
To check the safety stop circuit, enter the INPUT / OUTPUT screen in Test Mode and
ensure that the emergency stop button is released (OFF). Then check the footrest
switches looking at the
Footrest detection
line. The reading on this line should be
OFF
when both footrests are pressed. The reading is
ON
when any of the footrests is released.
If the message is wrong, the technician should check the switches. The circuit is shown in
the wiring diagrams.
If any of the footrests is not pressed along the play, the following message will be displayed
on the screen.
If the security circuit seems to be OK, but the motion system remains disabled, you have
to check the error messages provided by the driver. Those messages can be consulted by
selecting the option
Check error log
in the MOTION SYSTEM menu.
PLACE FEET ON THE FOOTRESTS
Summary of Contents for Ring Riders
Page 4: ...GAELCO RING RIDERS 4 ...
Page 55: ...GAELCO RING RIDERS 55 NOTES ...
Page 59: ...59 GAELCO RING RIDERS ...
Page 69: ...69 GAELCO RING RIDERS ...
Page 75: ...75 GAELCO RING RIDERS ...
Page 77: ...77 GAELCO RING RIDERS ...
Page 81: ...GAELCO RING RIDERS 81 ...
Page 83: ...83 GAELCO RING RIDERS ...
Page 86: ...86 GAELCO RING RIDERS 11 1 CABINET WIRING 1 11 WIRING DIAGRAMS ...
Page 87: ...87 GAELCO RING RIDERS 11 2 CABINET WIRING 2 ...
Page 88: ...88 GAELCO RING RIDERS 11 3 POWER 220ACV GROUND WIRING ...
Page 89: ...89 GAELCO RING RIDERS 11 4 PLATFORM WIRING ...