38
Chain drive
Assembly and operating instructions
ELTRAL K30 | ELTRAL K30 Synchro
The connection is to be carried out according to the following wiring diagrams.
1
2
3
4
5
+
24 V DC
–
1
1
2
2
4
4
3
3
5
5
24 V DC
Colour
Function
Black "1"
Black "2"
Red
Black "3"
White
Drive 1
Drive 2
(not assigned)
(not used)
Cable
1
2
4
5
3
N
110/230 V~
F
1
1
2
2
4
4
3
3
5
5
110/230 V~ 50/60 Hz
Cable Colour
Function
Light blue
Black
Red
Brown
White
Drive 1
Drive 2
If, after connection, the running direction
is contrary to that of the arrows on the wall
switch, the wires 2 and 3 must be inverted
If, after connection, the running direction
is contrary to that of the arrows on the wall
switch, the wires 1 and 2 must be inverted