background image

PROGRAM FLOW CHART

PROGRAM FLOW CHART

12

13

PROGRAM SELECT

      BA

TT

 MEMOR

Y

ENTER

ST

AR

T

BA

TT

 MEMOR

Y [1]

ENTER SET

ENTER

ST

AR

T

BA

TT

 TYPE

LiPo

BA

TT

 VOL

TS

       7.4V ( 2S )

CHARGE CURRENT

                           4.9A

DSCH CURRENT

                           2.2A

DSCH VOL

TAGE

                 3.0V/CELL

TVC=YOUR RISK

                         4.20V

ENTER

ST

AR

T

ENTER

ST

AR

T

PROGRAM SELECT

      SYSTEM SET

->

Rest 

Time

CHG>DCHG    10Min

VERSION

                            1.00

ENTER

ST

AR

T

SAFETY

 TIME

ON                  120Min

Capacity Cut-Of

f

ON             5000mAH

Key Beep             ON

Buzzer                 ON

Input Power Low

Cut-Of

f              1

1.0V

Ext. 

Temp              0C

Int. 

Temp              37C

LOAD F

ACT

OR

Y SET

                       ENTER

Stop

Batt 

Type

SA

VE PROGRAM 

                      ENTER

SA

VE PROGRAM 

SA

VE….

BA

TT

 MEMOR

Y [1]

LiPo  7.4V (2S )

ENTER

ST

AR

T

BA

TT

 MEMOR

Y [1]

C:4.9A

  D:2.2A

ENTER CHARGER

LOAD……

LiPo BALANCE

4.9A

      7.4V(2S)

LiPo CHARGE

4.9A

      7.4V(2S)

LiPo F

AST

 CHG

4.9A

      7.4V(2S)

LiPo ST

ORAGE 

4.9A

      7.4V(2S)

LiPo DISCHARGE

2.2A

      7.4V(2S)

BA

TT

 MEMOR

Y 2

NiMH   2.4V (2S)

BA

TT

 TYPE

MiMH

BA

TT

 VOL

TS

    

2.4V (2S)

ENTER

ST

AR

T

CHARGE CURRENT

                          3.3A

TRICKLE

              100mA

PEAK DELA

Y

                         1Min

DSCH CURRENT

                          2.2A

DSCH VOL

TAGE

    

1.1V/CELL

DEL

TA

 PEAK SENSE

     

4Mv/C

SA

VE PROGRAM 

ENTER

BA

TT

 MEMOR

Y 3

Pb   4V (2S)

ENTER

ST

AR

T

BA

TT

 TYPE

Pb

BA

TT

 VOL

TS

                   4.0V (2S)

CHARGE CURRENT

                          3.3A

DSCH CURRENT

      

1.5A

DSCH VOL

TAGE

    

1.7V/CELL

SA

VE PROGRAM 

ENTER

PROGRAM SELECT

            Pb BA

TT

 

ENTER

ST

AR

T

Pb CHARGE

2.0A

     2.0V (1P)

Pb DISCHARGE

0.1A

     2.0V (1P)

PROGRAM SELECT

          NiCD BA

TT

NiCD CHARGE

CURRENT

     2.0A

ENTER

ST

AR

T

NiCD DISCHARGE

0.1A

       CUT

: 1.0V

NiCD CYCLE

CHG>DCHG     

   

  1

PROGRAM SELECT

          NiMH BA

TT

 

ENTER

ST

AR

T

NiMH CHARGE

CURRENT

     2.0A

NiMH DISCHARGE

0.1A

       CUT

: 1.0V

NiMH CYCLE

CHG>DCHG          1

PROGRAM SELECT

           LiPo BA

TT

LiPo BALANCE

2.0A

     7.4V (2S)

LiPo CHARGE

2.0A

         7.4V (2S)

LiPo F

AST

 CHG

2.0A

     7.4V (2S)

LiPo ST

ORAGE

2.0A

     7.4V (2S)

LiPo DISCHARGE

2.0A

         7.4V (2S)

ENTER

ST

AR

T

PROGRAM SELECT

           Lilo BA

TT

Lilo BALANCE

2.0A

     7.2V (2S)

Lilo CHARGE

2.0A

     7.2V (2S)

Lilo F

AST

 CHG

2.0A

    7.2V (2S)

Lilo ST

ORAGE

2.0A

    7.2V (2S)

Lilo DISCHARGE

2.0A

     7.2V (2S)

ENTER

ST

AR

T

PROGRAM SELECT

           LiFe BA

TT

LiFe BALANCE

2.0A

     6.6V (2S)

LiFe CHARGE

2.0A

     6.6V (2S)

LiFe F

AST

 CHG

2.0A

    6.6V (2S)

LiFe ST

ORAGE

2.0A

    6.6V (2S)

LiFe DISCHARGE

2.0A

     6.6V (2S)

ENTER

ST

AR

T

ENTER

ST

AR

T

PROGRAM SELECT

 

Li   BA

TT

 METER

4.20   4.19    4.19 V

0.00   0.00    0.00 V

MAIN 0.00V  

H0.000V     L0.000V

NiCD RE-PEAK

                         1

NiMH RE-PEAK

                         1

NiMH 

Auto CHARGE

CURRENT

     2.0A

NiCD 

Auto CHARGE

CURRENT

     2.0A

TEMPERA

TURE

CUT

-OFF          50C

TEMPERA

TURE

CUT

-OFF          50C

TEMPERA

TURE

CUT

-OFF          50C

Summary of Contents for G6

Page 1: ...Balance Charger Discharger Ver 1 30 INSTRUCTION MANUAL Products by G FORCE Inc www gforce hobby jp Mare kanda Bld 9F 1 3 1 Kajicho Chiyoda ku Tokyo 101 0044 JAPAN Copyright 2014 G FORCE Inc All Right...

Page 2: ...lead Pb batteries are charged using the CC CV method The fan cooling system is so smart and efficient The fan speed is controlled by internal temperature sensor The user can check battery s total volt...

Page 3: ...ancing Individual Cells Battery Discharging During the process of discharging can monitor and balance each cell of the battery individually Error message will be indicated and the process will be ende...

Page 4: ...e principle of the Delta peak voltage detection When the battery s voltage exceeds the threshold the process will be terminated automatically SPECIAL FEATURES Automatic Charging Current Limit You can...

Page 5: ...al charge circuit or a protection circuit A battery pack which consists of different types of cells including different manufacturers A battery that is already fully charged or just slightly discharge...

Page 6: ...the battery s capacity is calculated by multiplying single the battery s capacity by the number of cells bearing in mind that total voltage stays the same If the voltage is imbalanced it may cause a f...

Page 7: ...the charger first and only then to the battery Reverse the sequence when disconnecting the pack Balance socket The balance wire attached to the battery must be connected to the charger with the black...

Page 8: ...T VOLTS 4 0V 2S CHARGE CURRENT 3 3A DSCH CURRENT 1 5A DSCH VOLTAGE 1 7V CELL SAVE PROGRAM ENTER PROGRAM SELECT Pb BATT ENTER START Pb CHARGE 2 0A 2 0V 1P Pb DISCHARGE 0 1A 2 0V 1P PROGRAM SELECT Ni C...

Page 9: ...tteries with a balance lead in the balance mode only The left side of the first line shows the type of battery you choose The value on the left of the second line of the charger is current user set Af...

Page 10: ...l you can start charging by press Start Enter button If LITHIUM BATTERY LiPo LiFe LiIon PROGRAM Start Enter Current voltage battery Supplied capacity Charge current Charging time Number of cells not p...

Page 11: ...key to make it blink then change the value using or key The value will be stored by pressing Start Enter key once To start the process press Start Enter button for more than 3 seconds CHARGING OF BAT...

Page 12: ...ts the end of discharging Elapsed time Charged capacity Battery type Charge current Battery voltage NiMH RE PEAK 1 NiMH 2 0A 9 59V RPC 000 33 00017 Re peak cycle 1 shows on the display Press the Start...

Page 13: ...d of process DISCHARGING OF PB BA TTER Y Set discharge current on the left and final voltage on the right The discharge current ranges from 0 1 to 2 0A To start the process press Start Enter key for m...

Page 14: ...0 1A 2 0A Set the discharge voltage which can be adjusted 3 0V CELL 3 3V CELL Set the voltage and number of cells along with the normal voltage 1 6S Set the charge current which can be adjusted 0 1 10...

Page 15: ...N 120Min User set up starting screen The battery is on the cyclic process of charge and discharge can often become warm after charge or discharge period The program can insert a time delay to occur af...

Page 16: ...re 11 9 set this number as the value for safety timer setting If the charger stopped at this threshold about 140 of the capacity will have been fed into the battery SYSTEM SET UP VARIOUS INFORMATION D...

Page 17: ...TAGE INVALID Voltage of one cell in the battery pack is invalid The external temperature of the unit goes too high EXT TEMP TOO HI OVER CHARGE CAPACITY LIMIT The battery capacity is more than the maxi...

Page 18: ...employ for using operating and maintaining the device For this reason we are obliged to deny all liability for loss damage or costs which are incurred due to the incompetent or incorrect use and oper...