background image

18

19

LITHIUM BATTERY(LiPo/LiFe/LiIon)PROGRAM

Number
of
cells

Elapsed
time

Charge 
or discharge
current

Supplied
capacity

Current
voltage
battery

This  screen  shows  the  real-time  status 
charging.  Press  Batt  Type/Stop  key  once  to 
stop the charge process.

DISCHARGING LITHIUM BATTERY

Number
of
cells

elapsed
time

Battery
voltage

Discharged
capacity

discharge
 current

The  value  of  discharge  current  on  the  left  can 
not  exceed  1C,  and  the  value  on  the  right  can 
not  be  under  the  voltage  recommended  by  the 
manufacturer  to  avoid  deep  discharging.  Press 
Start/Enter  for  more  than  3  seconds  to  start 
discharging.

This  shows  the  real-time  status  of  discharging, 
you  can  press  Batt  Type/Stop  key  to  stop 
discharging.

This  displays  the  number  of  cells  you  set  up 
and  the  processor  detects.  s  detected  by  the 
charger  and    cells  set  by  you  at  the  previous 
screen.  If  both  numbers  are  identical  you  can 
start  charging  by  press  Start/Enter  button.  If 
not,  press  Batt Type/Stop  button  to  go  back  to 
previous  screen  to  carefully  check  the  number 
of cells of the battery pack before going ahead.

 Start
 Enter

Start
Enter

Batt type
   Stop

'> 3 seconds  

'

 Start
 Enter

NIMH/NICD BATTERY PROGRAM

These  programs  are  for  charging  or  discharging  NiMH  (Nickel-Metal-
Hydride)  or  NiCd  (Nickel-Cadmium)  battery  commonly  used  for  R/C  model 
aplications. To alter the value at the display, press Start/Enter key to make it 
blink then change the value using        or        key. The value will be stored 
by pressing Start/Enter key once.
To start the process, press Start/ Enter button for more than 3 seconds.

CHARGING OF 

/

 BATTERY

NIMH NICD

The charger will charge NiCd and NiMh batteries using the charge
current set by the user.

NiMH CHARGE
CURRENT     2.0A

Battery
type

Elapsed
time

Charged
capacity

Battery
type

Charge 
current

Battery
voltage

The screen displays the current state of charging.
To stop the process, press Batt type/Stop key once.
The audible sound indicates you the end of process.

This  program  is  for  charging  of  NiCd/NiMH 
batteries associated with R/C models applications. 
You can press Start/Enter key to make it blink and 
then          or            to  change  the  parameter  value. 
Press START/ENTER key to store the value.

In  this  program  the  charger  detects  the  condition  of  the  battery  which  is 
connected to the output and automatically charges the battery. In this mode, 
you should set up the upper limit of the charge current to avoid damage by 
excessive  feeding  current.  Some  batteries  of  low  resistance  and  capacity 
can lead to higher current in the auto charging mode.

N i M H A u t o  C H A R G E
C U R R E N T      2 . 0 A 

This program is for charging of NiCd/NiMH batteries. 
You can press the Start/Enter button to make it blink 
and  then  press  the        /        button  to  change  the 
parameter  value.  Press  the  Start/Enter  button  more 
than 3 seconds to start the charging process.

Battery
type

Start
Enter

Batt type
   Stop

'> 3 seconds  '

CHARGING 

/

 BATTERY IN THE AUTO CHARGE MODE

NIMH NICD

Start
Enter

Batt type
   Stop

'> 3 seconds  '

- +

- +

- +

Summary of Contents for G6

Page 1: ...Balance Charger Discharger Ver 1 30 INSTRUCTION MANUAL Products by G FORCE Inc www gforce hobby jp Mare kanda Bld 9F 1 3 1 Kajicho Chiyoda ku Tokyo 101 0044 JAPAN Copyright 2014 G FORCE Inc All Right...

Page 2: ...lead Pb batteries are charged using the CC CV method The fan cooling system is so smart and efficient The fan speed is controlled by internal temperature sensor The user can check battery s total volt...

Page 3: ...ancing Individual Cells Battery Discharging During the process of discharging can monitor and balance each cell of the battery individually Error message will be indicated and the process will be ende...

Page 4: ...e principle of the Delta peak voltage detection When the battery s voltage exceeds the threshold the process will be terminated automatically SPECIAL FEATURES Automatic Charging Current Limit You can...

Page 5: ...al charge circuit or a protection circuit A battery pack which consists of different types of cells including different manufacturers A battery that is already fully charged or just slightly discharge...

Page 6: ...the battery s capacity is calculated by multiplying single the battery s capacity by the number of cells bearing in mind that total voltage stays the same If the voltage is imbalanced it may cause a f...

Page 7: ...the charger first and only then to the battery Reverse the sequence when disconnecting the pack Balance socket The balance wire attached to the battery must be connected to the charger with the black...

Page 8: ...T VOLTS 4 0V 2S CHARGE CURRENT 3 3A DSCH CURRENT 1 5A DSCH VOLTAGE 1 7V CELL SAVE PROGRAM ENTER PROGRAM SELECT Pb BATT ENTER START Pb CHARGE 2 0A 2 0V 1P Pb DISCHARGE 0 1A 2 0V 1P PROGRAM SELECT Ni C...

Page 9: ...tteries with a balance lead in the balance mode only The left side of the first line shows the type of battery you choose The value on the left of the second line of the charger is current user set Af...

Page 10: ...l you can start charging by press Start Enter button If LITHIUM BATTERY LiPo LiFe LiIon PROGRAM Start Enter Current voltage battery Supplied capacity Charge current Charging time Number of cells not p...

Page 11: ...key to make it blink then change the value using or key The value will be stored by pressing Start Enter key once To start the process press Start Enter button for more than 3 seconds CHARGING OF BAT...

Page 12: ...ts the end of discharging Elapsed time Charged capacity Battery type Charge current Battery voltage NiMH RE PEAK 1 NiMH 2 0A 9 59V RPC 000 33 00017 Re peak cycle 1 shows on the display Press the Start...

Page 13: ...d of process DISCHARGING OF PB BA TTER Y Set discharge current on the left and final voltage on the right The discharge current ranges from 0 1 to 2 0A To start the process press Start Enter key for m...

Page 14: ...0 1A 2 0A Set the discharge voltage which can be adjusted 3 0V CELL 3 3V CELL Set the voltage and number of cells along with the normal voltage 1 6S Set the charge current which can be adjusted 0 1 10...

Page 15: ...N 120Min User set up starting screen The battery is on the cyclic process of charge and discharge can often become warm after charge or discharge period The program can insert a time delay to occur af...

Page 16: ...re 11 9 set this number as the value for safety timer setting If the charger stopped at this threshold about 140 of the capacity will have been fed into the battery SYSTEM SET UP VARIOUS INFORMATION D...

Page 17: ...TAGE INVALID Voltage of one cell in the battery pack is invalid The external temperature of the unit goes too high EXT TEMP TOO HI OVER CHARGE CAPACITY LIMIT The battery capacity is more than the maxi...

Page 18: ...employ for using operating and maintaining the device For this reason we are obliged to deny all liability for loss damage or costs which are incurred due to the incompetent or incorrect use and oper...

Reviews: