26
27
LITHIUM BATTERY METER
PROGRAM SELECT
Li BATT METER
Press the Start/Enter button to enter the Lithium
Battery Meter.
4.19 4.15 4.18V
0.00 0.00 0.00V
The screen indicate each cell's voltage.
MAIN 12.52V
H4.190V L4.160V
The screen indicate the total voltage, the highest
voltage, the lowest voltage.
Start
Enter
SYSTEM SET UP
It will be operated with the default value of the essential user settings when
it is connected to a DC 11~18V batttery for the first time.The screen
displays the following information in sequence and the user can change the
value of parameter on each screen.
When you are willing to alter the parameter value in the program, press
Start/Enter key to make it blink then change the value with or key.
The value will be stored by pressing Start/Enter key once.
PROGRAM SELECT
SYSTEM SET
Rest Time
CHG
>
DCHG 10Min
SAFETY TIME
ON 120Min
User set up starting screen.
The battery is on the cyclic process of charge and
discharge can often become warm after charge or
discharge period. The program can insert a time
delay to occur after each charge and discharge
process to allow the battery adequate time to cool
down before being subjected to the next process.
The value ranges from 1 to 60 minutes.
When you start a charge process, the integral
safety timer automatically starts running at the
same time. This is programmed to prevent
overcharge the battery if it proves to be faulty, or
if the termination circuit cannot detect the battery
full. The value for the safety timer should be
generous enough to allow a full charge of the
battery.
Safe timer Calculation
When charging NiCd or NiMH batteries, divide
the capacity by current, then divide the result by
The user can check battery's total voltage, the highest voltage, the
lowest voltage and each cell's voltage.
Please connect the battery to the charger main battery lead to battery
socket and balance wires to balance socket.