background image

26

27

LITHIUM  BATTERY METER

PROGRAM  SELECT
Li   BATT  METER

Press  the  Start/Enter  button  to  enter  the  Lithium 
Battery Meter.

4.19  4.15  4.18V
0.00  0.00  0.00V

The screen indicate each cell's voltage.

MAIN 12.52V
H4.190V   L4.160V

The  screen  indicate  the  total  voltage,  the  highest 
voltage, the lowest voltage.

 Start
 Enter

SYSTEM SET UP

It will be operated with the default value of the essential user settings when 
it  is  connected  to  a  DC  11~18V  batttery  for  the  first  time.The  screen 
displays the following information in sequence and the user can change the 
value of parameter on each screen.
When  you  are  willing  to  alter  the  parameter  value  in  the  program,  press 
Start/Enter key to make it blink then change the value with      or      key. 
The value will be stored by pressing Start/Enter key once.

PROGRAM SELECT
      SYSTEM SET

Rest Time
CHG

DCHG  10Min

SAFETY TIME
ON        120Min

User set up starting screen.

The battery is on the cyclic process of charge and 
discharge can often become warm after charge or 
discharge  period.  The  program  can  insert  a  time 
delay  to  occur  after  each  charge  and  discharge 
process to allow the battery adequate time to cool 
down before being subjected to the next process. 
The value ranges from 1 to 60 minutes.

When  you  start  a  charge  process,  the  integral 
safety  timer  automatically  starts  running  at  the 
same  time.  This  is  programmed  to  prevent 
overcharge the battery if it proves to be faulty, or 
if the termination circuit cannot detect the battery 
full.  The  value  for  the  safety  timer  should  be 
generous  enough  to  allow  a  full  charge  of  the 
battery.
Safe timer Calculation
When  charging  NiCd  or  NiMH  batteries,  divide 
the  capacity  by  current,  then  divide  the  result  by 

The  user  can  check  battery's  total  voltage,  the  highest  voltage,  the 
lowest voltage and each cell's voltage.
Please connect the battery to the charger main battery lead to battery 
socket and balance wires to balance socket.

Summary of Contents for G6

Page 1: ...Balance Charger Discharger Ver 1 30 INSTRUCTION MANUAL Products by G FORCE Inc www gforce hobby jp Mare kanda Bld 9F 1 3 1 Kajicho Chiyoda ku Tokyo 101 0044 JAPAN Copyright 2014 G FORCE Inc All Right...

Page 2: ...lead Pb batteries are charged using the CC CV method The fan cooling system is so smart and efficient The fan speed is controlled by internal temperature sensor The user can check battery s total volt...

Page 3: ...ancing Individual Cells Battery Discharging During the process of discharging can monitor and balance each cell of the battery individually Error message will be indicated and the process will be ende...

Page 4: ...e principle of the Delta peak voltage detection When the battery s voltage exceeds the threshold the process will be terminated automatically SPECIAL FEATURES Automatic Charging Current Limit You can...

Page 5: ...al charge circuit or a protection circuit A battery pack which consists of different types of cells including different manufacturers A battery that is already fully charged or just slightly discharge...

Page 6: ...the battery s capacity is calculated by multiplying single the battery s capacity by the number of cells bearing in mind that total voltage stays the same If the voltage is imbalanced it may cause a f...

Page 7: ...the charger first and only then to the battery Reverse the sequence when disconnecting the pack Balance socket The balance wire attached to the battery must be connected to the charger with the black...

Page 8: ...T VOLTS 4 0V 2S CHARGE CURRENT 3 3A DSCH CURRENT 1 5A DSCH VOLTAGE 1 7V CELL SAVE PROGRAM ENTER PROGRAM SELECT Pb BATT ENTER START Pb CHARGE 2 0A 2 0V 1P Pb DISCHARGE 0 1A 2 0V 1P PROGRAM SELECT Ni C...

Page 9: ...tteries with a balance lead in the balance mode only The left side of the first line shows the type of battery you choose The value on the left of the second line of the charger is current user set Af...

Page 10: ...l you can start charging by press Start Enter button If LITHIUM BATTERY LiPo LiFe LiIon PROGRAM Start Enter Current voltage battery Supplied capacity Charge current Charging time Number of cells not p...

Page 11: ...key to make it blink then change the value using or key The value will be stored by pressing Start Enter key once To start the process press Start Enter button for more than 3 seconds CHARGING OF BAT...

Page 12: ...ts the end of discharging Elapsed time Charged capacity Battery type Charge current Battery voltage NiMH RE PEAK 1 NiMH 2 0A 9 59V RPC 000 33 00017 Re peak cycle 1 shows on the display Press the Start...

Page 13: ...d of process DISCHARGING OF PB BA TTER Y Set discharge current on the left and final voltage on the right The discharge current ranges from 0 1 to 2 0A To start the process press Start Enter key for m...

Page 14: ...0 1A 2 0A Set the discharge voltage which can be adjusted 3 0V CELL 3 3V CELL Set the voltage and number of cells along with the normal voltage 1 6S Set the charge current which can be adjusted 0 1 10...

Page 15: ...N 120Min User set up starting screen The battery is on the cyclic process of charge and discharge can often become warm after charge or discharge period The program can insert a time delay to occur af...

Page 16: ...re 11 9 set this number as the value for safety timer setting If the charger stopped at this threshold about 140 of the capacity will have been fed into the battery SYSTEM SET UP VARIOUS INFORMATION D...

Page 17: ...TAGE INVALID Voltage of one cell in the battery pack is invalid The external temperature of the unit goes too high EXT TEMP TOO HI OVER CHARGE CAPACITY LIMIT The battery capacity is more than the maxi...

Page 18: ...employ for using operating and maintaining the device For this reason we are obliged to deny all liability for loss damage or costs which are incurred due to the incompetent or incorrect use and oper...

Reviews: