G-Force G6 Instruction Manual Download Page 13

22

23

PB( LEAD-SULPHURIC ACID) BATTERY PROGRAM

This  is  programmed  for  charging  Pb(lead-sulphuric  acid)  battery  with 

nominal voltage from 2 to 20V. Pb batteries are totally different from NiCd or 

NiMH batteries. They can only deliver relatievely lower current compare to 

their  capacity,  and  similar  restrictions  definitely  apply  to  charge.  So  the 

optimal charge current will be 1/10 of the capacity. Pb batteries must not be 

charged  rapidly.  Always  follow  the  instruction  is  supplied  by  the 

manufacturer of battery.

When  you  are  willing  to  alter  the  parameter  value  in  the  program,  press 

Start/Enter key to make it blink then change the value with     or       key. 

The value will be stored by pressing Start/Enter key once.

CHARGING OF PB BA TTER Y

Battery

type

Elapsed

time

Charge 

current

Battery

voltage

Charged

capacity

Set  up  the  charge  current  on  the  left  and  the 

nominal voltage of the battery on the right. The 

charge  current  ranges  from  0.1  to  10.0A  and 

the voltage should be matched with the battery 

being charged.

Start  the  charge  process  by  pressing 

Start/Enter key for more than 3 seconds.

The  screen  displays  the  state  of  charging 

process.  To  stop  charging  forcibly,  press  Batt 

type/Stop key once.

The audible sound indicates you at the end of 

process.

DISCHARGING OF PB BA

TTER Y

Set  discharge  current  on  the  left  and  final 

voltage  on  the  right.  The  discharge  current 

ranges from 0.1 to 2.0A.

To  start  the  process,  press  Start/Enter  key  for 

more than 3 seconds.

Battery

type

Elapsed

time Discharge 

current

Battery

voltage

Discharged

capacity

The  screen  displays  the  current  state  of 

discharge. You  can  alter  the  discharge  current 

by pressing Start/Enter key during the process. 

Once you change the current value, store it by 

pressing Start/Enter button again.

To  stop  discharging  press  Batt  Type/Stop  key 

once.  The  audible  sound  indicates  you  at  the 

end of process.

The free “Charge Master” software gives you unparalleled ability to operate 

the  charger  through  the  computer.  You  can  monitor  pack  voltage,  cell 

voltage  and  other  data  during  the  charging,  view  charge  date  in  real-time 

graphs.  And  you  can  initiate,  control  charging  and  update  firmware  from 

“Charge Master”. 

In  order  to  connect  the  charger  to  the  computer  and  use  the  “Charge 

Master”, you are required to use a USB cable which is not included in this 

package. The cable must be terminated on one end with  “A” plug and the 

opposite end is terminated with “micro”  plug which can connect to charger 

directly.

The  “Charge  Master”  can  be  download  from www.gforce-hobby.jp

USING THE CHARGE CONTROL SOFTWARE

 “CHARGE MASTER”

Start

Enter

Batt type

   Stop

'> 3 seconds  '

Start

Enter

Batt type

   Stop

'> 3 seconds  '

- +

- +

- +

- +

PB( LEAD-SULPHURIC ACID) BATTERY PROGRAM

Summary of Contents for G6

Page 1: ...Balance Charger Discharger Ver 1 30 INSTRUCTION MANUAL Products by G FORCE Inc www gforce hobby jp Mare kanda Bld 9F 1 3 1 Kajicho Chiyoda ku Tokyo 101 0044 JAPAN Copyright 2014 G FORCE Inc All Right...

Page 2: ...lead Pb batteries are charged using the CC CV method The fan cooling system is so smart and efficient The fan speed is controlled by internal temperature sensor The user can check battery s total volt...

Page 3: ...ancing Individual Cells Battery Discharging During the process of discharging can monitor and balance each cell of the battery individually Error message will be indicated and the process will be ende...

Page 4: ...e principle of the Delta peak voltage detection When the battery s voltage exceeds the threshold the process will be terminated automatically SPECIAL FEATURES Automatic Charging Current Limit You can...

Page 5: ...al charge circuit or a protection circuit A battery pack which consists of different types of cells including different manufacturers A battery that is already fully charged or just slightly discharge...

Page 6: ...the battery s capacity is calculated by multiplying single the battery s capacity by the number of cells bearing in mind that total voltage stays the same If the voltage is imbalanced it may cause a f...

Page 7: ...the charger first and only then to the battery Reverse the sequence when disconnecting the pack Balance socket The balance wire attached to the battery must be connected to the charger with the black...

Page 8: ...T VOLTS 4 0V 2S CHARGE CURRENT 3 3A DSCH CURRENT 1 5A DSCH VOLTAGE 1 7V CELL SAVE PROGRAM ENTER PROGRAM SELECT Pb BATT ENTER START Pb CHARGE 2 0A 2 0V 1P Pb DISCHARGE 0 1A 2 0V 1P PROGRAM SELECT Ni C...

Page 9: ...tteries with a balance lead in the balance mode only The left side of the first line shows the type of battery you choose The value on the left of the second line of the charger is current user set Af...

Page 10: ...l you can start charging by press Start Enter button If LITHIUM BATTERY LiPo LiFe LiIon PROGRAM Start Enter Current voltage battery Supplied capacity Charge current Charging time Number of cells not p...

Page 11: ...key to make it blink then change the value using or key The value will be stored by pressing Start Enter key once To start the process press Start Enter button for more than 3 seconds CHARGING OF BAT...

Page 12: ...ts the end of discharging Elapsed time Charged capacity Battery type Charge current Battery voltage NiMH RE PEAK 1 NiMH 2 0A 9 59V RPC 000 33 00017 Re peak cycle 1 shows on the display Press the Start...

Page 13: ...d of process DISCHARGING OF PB BA TTER Y Set discharge current on the left and final voltage on the right The discharge current ranges from 0 1 to 2 0A To start the process press Start Enter key for m...

Page 14: ...0 1A 2 0A Set the discharge voltage which can be adjusted 3 0V CELL 3 3V CELL Set the voltage and number of cells along with the normal voltage 1 6S Set the charge current which can be adjusted 0 1 10...

Page 15: ...N 120Min User set up starting screen The battery is on the cyclic process of charge and discharge can often become warm after charge or discharge period The program can insert a time delay to occur af...

Page 16: ...re 11 9 set this number as the value for safety timer setting If the charger stopped at this threshold about 140 of the capacity will have been fed into the battery SYSTEM SET UP VARIOUS INFORMATION D...

Page 17: ...TAGE INVALID Voltage of one cell in the battery pack is invalid The external temperature of the unit goes too high EXT TEMP TOO HI OVER CHARGE CAPACITY LIMIT The battery capacity is more than the maxi...

Page 18: ...employ for using operating and maintaining the device For this reason we are obliged to deny all liability for loss damage or costs which are incurred due to the incompetent or incorrect use and oper...