G-Force G6 Instruction Manual Download Page 12

20

21

N i M H  2 . 0 A  9 . 5 2 V
A U T 0 0 0 : 1 3  0 0 0 0 0

CHARGING 

/

 BATTERY IN RE-PEAK

CHARGE MODE

NIMH NICD

Re-peak  Charge  Mode  (NiCd  and  NiMH  batteries  only):  In  re-peak  charge 
mode, the charger can peak charge the battery once, twice or three times in 
a row automatically. This is good for confirming the battery is fully charged, 
and  for  checking  how  well  the  battery  receives  fast  charges. A  five  minute 
cool-off delay occurs after each re-peak charge. See the diagram below for 
using re-peak charge mode. To start charging, press the Start/Enter button 
for 3 seconds.

NIMH/NICD BATTERY PROGRAM

The screen indicates the discharging state. You 
can  press  Start/Enter  key  to  alter  discharge 
current.  Press  Start/Enter  again  to  store  the 
value.  Press  Batt  Type/Stop  key  to  stop 
discharging.  The  emitted  sound  alerts  the  end 
of discharging.

Elapsed
time

Charged
capacity

Battery
type

Charge 
current

Battery
voltage

N i M H R E - P E A K
                 1

N i M H  2 . 0 A  9 . 5 9 V
R P C 0 0 0 : 3 3  0 0 0 1 7

“Re-peak  cycle:  1”  shows  on  the  display.  Press 
the  Start/Enter  button  to  make  the  re-peak  cycle 
number blink and press the      /      button to find 
the desired number of times to re-peak. Press the 
Start/Enter button to confirm selection.

Battery
type

Charge 
current

Battery
voltage

Elapsed
time

Charged
capacity

CHARGE/DISCHARGE & DISCHARGE/CHARGE CYCLE
OF NIMH/NICD BATTERY

Battery
type

Elapsed
time

Battery
voltage

Discharged
or charged
capacity

Discharge
or charge 
current

NiMH CYCLE
 CHG

DCHG       1

NiMH  1.0A   7.42V
C>D  022:45  00890

You  can  set  up  sequence  on  the  left  and  the 
number  of  cycles  on  the  right.  Range  of  the 
cycle number is 1-3.

Press Batt Type/Stop key to stop program, you 
can  press  Start/Enter  key  to  alter  charge 
current.  The  sound  indicates  the  end  of 
program. 

NIMH/NICD BATTERY PROGRAM

 Start
 Enter

Start
Enter

Batt type
   Stop

'> 3 seconds  '

- +

- +

- +

Summary of Contents for G6

Page 1: ...Balance Charger Discharger Ver 1 30 INSTRUCTION MANUAL Products by G FORCE Inc www gforce hobby jp Mare kanda Bld 9F 1 3 1 Kajicho Chiyoda ku Tokyo 101 0044 JAPAN Copyright 2014 G FORCE Inc All Right...

Page 2: ...lead Pb batteries are charged using the CC CV method The fan cooling system is so smart and efficient The fan speed is controlled by internal temperature sensor The user can check battery s total volt...

Page 3: ...ancing Individual Cells Battery Discharging During the process of discharging can monitor and balance each cell of the battery individually Error message will be indicated and the process will be ende...

Page 4: ...e principle of the Delta peak voltage detection When the battery s voltage exceeds the threshold the process will be terminated automatically SPECIAL FEATURES Automatic Charging Current Limit You can...

Page 5: ...al charge circuit or a protection circuit A battery pack which consists of different types of cells including different manufacturers A battery that is already fully charged or just slightly discharge...

Page 6: ...the battery s capacity is calculated by multiplying single the battery s capacity by the number of cells bearing in mind that total voltage stays the same If the voltage is imbalanced it may cause a f...

Page 7: ...the charger first and only then to the battery Reverse the sequence when disconnecting the pack Balance socket The balance wire attached to the battery must be connected to the charger with the black...

Page 8: ...T VOLTS 4 0V 2S CHARGE CURRENT 3 3A DSCH CURRENT 1 5A DSCH VOLTAGE 1 7V CELL SAVE PROGRAM ENTER PROGRAM SELECT Pb BATT ENTER START Pb CHARGE 2 0A 2 0V 1P Pb DISCHARGE 0 1A 2 0V 1P PROGRAM SELECT Ni C...

Page 9: ...tteries with a balance lead in the balance mode only The left side of the first line shows the type of battery you choose The value on the left of the second line of the charger is current user set Af...

Page 10: ...l you can start charging by press Start Enter button If LITHIUM BATTERY LiPo LiFe LiIon PROGRAM Start Enter Current voltage battery Supplied capacity Charge current Charging time Number of cells not p...

Page 11: ...key to make it blink then change the value using or key The value will be stored by pressing Start Enter key once To start the process press Start Enter button for more than 3 seconds CHARGING OF BAT...

Page 12: ...ts the end of discharging Elapsed time Charged capacity Battery type Charge current Battery voltage NiMH RE PEAK 1 NiMH 2 0A 9 59V RPC 000 33 00017 Re peak cycle 1 shows on the display Press the Start...

Page 13: ...d of process DISCHARGING OF PB BA TTER Y Set discharge current on the left and final voltage on the right The discharge current ranges from 0 1 to 2 0A To start the process press Start Enter key for m...

Page 14: ...0 1A 2 0A Set the discharge voltage which can be adjusted 3 0V CELL 3 3V CELL Set the voltage and number of cells along with the normal voltage 1 6S Set the charge current which can be adjusted 0 1 10...

Page 15: ...N 120Min User set up starting screen The battery is on the cyclic process of charge and discharge can often become warm after charge or discharge period The program can insert a time delay to occur af...

Page 16: ...re 11 9 set this number as the value for safety timer setting If the charger stopped at this threshold about 140 of the capacity will have been fed into the battery SYSTEM SET UP VARIOUS INFORMATION D...

Page 17: ...TAGE INVALID Voltage of one cell in the battery pack is invalid The external temperature of the unit goes too high EXT TEMP TOO HI OVER CHARGE CAPACITY LIMIT The battery capacity is more than the maxi...

Page 18: ...employ for using operating and maintaining the device For this reason we are obliged to deny all liability for loss damage or costs which are incurred due to the incompetent or incorrect use and oper...