BATTERY MEMORY SET
The charger can store up to 10 different charge/discharge profiles for your
convenience, and the stored profiles can be recalled quickly without having
to go through the setup process.
BATT MEMORY
【
1
】
ENTER SET
BATT TYPE
LiPo
Enter the battery memory program, you can change
the battery type(Lipo, Lilo, LiFe, NiMH, NiCd, Pb
battery), voltage, charge current by pressing the
Start/Enter button to make the value blink, the or
+ buttons to change the value, and Start/Enter
button once more to store the value and move to the
next value or screen. (Note: The battery used for this
example is a 2S(7.4V) Lipo battery.
DSCH CURRENT
2.2A
BATT VOLTS
7.4V(2S)
CHARGE CURRENT
4.9A
DSCH VOLTAGE
3.0V/CELL
Set the discharge current, which can be adjusted
(0.1A-2.0A).
Set the discharge voltage, which can be adjusted
(3.0V/CELL-3.3V/CELL).
Set the voltage and number of cells, along with the
normal voltage (1-6S).
Set the charge current, which can be adjusted(0.1-
10.0A).
TVC=YOUR RISK
4.20V
SAVE PROGRAM
SAVE
SAVE PROGRAM
ENTER
BATT MEMORY
【
1
】
LiPo 7.4V(2S)
BATT MEMORY
【
1
】
C:4.9A D:2.2A
ENTER CHARGER
LOAD……
next flash
TEMPERATURE
CUT-OFF 50C
Set the terminal voltage, which can be adjusted
(4.18-4.30V).
Save the program set by pressing the Start/Enter
button for more than three seconds.
This screen indicate the saved profile.
This screen indicates that the charge profile is being
loaded.
Once you've saved a charge profile, you can load
those settings to use later. To load a memory, you
have to press the Start/Enter Button for more than 3
seconds. Otherwise you only enter the setting mode.
BATTERY MEMORY SET
Set the cut-off temperature, which can be
adjusted(20 C
/
68 F-80 C
/
176 F).
Start
Enter
'> 3 seconds
'
Start
Enter
'> 3 seconds '
- +
- +
- +
- +
- +
- +