background image

06

WARNING  AND  SAFETY NOTES

07

These  warnings  and  safety  notes  are  particularly  important.  Please 
follow  the  instructions  for  maximum  safety;  otherwise  the  charger  and 
the battery can be damaged or at worst it can cause a fire.

The

 

allowable

 

DC input

 

voltage

 

is 11-18V

 

DC

.

Never  leave  the  charger  unattended  when  it  is  connected  to  its 
power  supply.  If  any  malfunction  is  found,  TERMINATE  THE 
PROCESS AT ONCE and refer to the operation manual.
Keep  the  charger  well  away  from  dust,  damp,  rain,  heat,  direct 
sunshine and vibration. Never drop it.

This  charger  and  the  battery  should  be  put  on  a  heat-resistant, 
non-flammable and non-conductive surface. Never place them on 
a  car  seat,  carpet  or  similar  surface.  Keep  all  flammable  volatile 
materials away from the operating area.

Make  sure  you  know  the  specifications  of  the  battery  to  be 
charged or discharged to ensure it meets the requirements of this 
charger.  If  the  program  is  set  up  incorrectly,  the  battery  and 
charger  may  be  damaged.  Fire  or  explosion  can  occur  due  to 
overcharging.  This  warranty  is  not  valid  for  any  damage  or 
subsequent  damage  arising  as  a  result  of  a  misuse  or  failure  to 
observe the procedures outlined in this manual. 

To avoid short circuiting between the charge lead, always connect 
the  charge  cable  to  the  charger  first,  then  connect  the  battery. 
Reverse the sequence when disconnecting.

Never

 

attempt

 

to

 

charge

 

or

 

discharge

 

the

 

following

 

types

of

 

batteries

:

A battery fitted with an integral charge circuit or a protection circuit

A battery pack which consists of different types of cells 
(including different manufacturers)
A battery that is already fully charged or just slightly discharged

Non-rechargeable batteries (pose an explosion hazard)

A faulty or damaged battery

WARNING  AND  SAFETY NOTES

Batteries installed in a device or which are electrically linked to 
other components
Batteries  that  are  not  expressly  stated  by  the  manufacturer  to 
be  suitable  for  the  currents  the  charger  delivers  during  the 
charge process

Please

 

bear

 

in

 

mind

 

the

 

following

 

points

 

before

 

commencing

  

charging

:

Did  you  select  the  appropriate  program  suitable  for  the  type  of 
battery you are charging?
Did you set up adequate current for charging or discharging?
Have  you  checked  the  battery  voltage?  Lithium  battery  packs 
can be wired in parallel and in series, i.e. a 2-cell pack can be 
3.7V (in parallel) or 7.4V (in series).
Have  you  checked  that  all  connections  are  firm  and  secure? 
Make sure there are no intermittent contacts at any point in the 
circuit.

Standard Battery Parameters

Be very careful to choose the correct voltage for different types of battery otherwise you
may cause damage to the batteries.  Incorrect settings could cause the cells to fire or
explode.

3.7V/cell

Nominal 
Voltage

Min. Discharge 
Voltage

Max Charge 
Voltage

Storage 
Voltage

Allowable 
Fast Charge

3.7V/cell

4.2V/cell

3.8V/cell

1C

3.0-3.3V/cell

LiPo

LiIon

3.6V/cell

4.1V/cell

1C

3.3V/cell

3.6V/cell

3.3V/cell

4C

LiFe

1.2V/cell

1.5V/cell

n/a

1C-2C

NiCd

1.2V/cell

1.5V/cell

n/a

1C-2C

MiMH

2.0V/cell

2.46V/cell

n/a

0.4C

Pb

2.9-3.2V/cell 2.6-2.9V/cell 0.1-1.1V/cell 0.1-1.1V/cell

1.8V/cell

Summary of Contents for G6

Page 1: ...Balance Charger Discharger Ver 1 30 INSTRUCTION MANUAL Products by G FORCE Inc www gforce hobby jp Mare kanda Bld 9F 1 3 1 Kajicho Chiyoda ku Tokyo 101 0044 JAPAN Copyright 2014 G FORCE Inc All Right...

Page 2: ...lead Pb batteries are charged using the CC CV method The fan cooling system is so smart and efficient The fan speed is controlled by internal temperature sensor The user can check battery s total volt...

Page 3: ...ancing Individual Cells Battery Discharging During the process of discharging can monitor and balance each cell of the battery individually Error message will be indicated and the process will be ende...

Page 4: ...e principle of the Delta peak voltage detection When the battery s voltage exceeds the threshold the process will be terminated automatically SPECIAL FEATURES Automatic Charging Current Limit You can...

Page 5: ...al charge circuit or a protection circuit A battery pack which consists of different types of cells including different manufacturers A battery that is already fully charged or just slightly discharge...

Page 6: ...the battery s capacity is calculated by multiplying single the battery s capacity by the number of cells bearing in mind that total voltage stays the same If the voltage is imbalanced it may cause a f...

Page 7: ...the charger first and only then to the battery Reverse the sequence when disconnecting the pack Balance socket The balance wire attached to the battery must be connected to the charger with the black...

Page 8: ...T VOLTS 4 0V 2S CHARGE CURRENT 3 3A DSCH CURRENT 1 5A DSCH VOLTAGE 1 7V CELL SAVE PROGRAM ENTER PROGRAM SELECT Pb BATT ENTER START Pb CHARGE 2 0A 2 0V 1P Pb DISCHARGE 0 1A 2 0V 1P PROGRAM SELECT Ni C...

Page 9: ...tteries with a balance lead in the balance mode only The left side of the first line shows the type of battery you choose The value on the left of the second line of the charger is current user set Af...

Page 10: ...l you can start charging by press Start Enter button If LITHIUM BATTERY LiPo LiFe LiIon PROGRAM Start Enter Current voltage battery Supplied capacity Charge current Charging time Number of cells not p...

Page 11: ...key to make it blink then change the value using or key The value will be stored by pressing Start Enter key once To start the process press Start Enter button for more than 3 seconds CHARGING OF BAT...

Page 12: ...ts the end of discharging Elapsed time Charged capacity Battery type Charge current Battery voltage NiMH RE PEAK 1 NiMH 2 0A 9 59V RPC 000 33 00017 Re peak cycle 1 shows on the display Press the Start...

Page 13: ...d of process DISCHARGING OF PB BA TTER Y Set discharge current on the left and final voltage on the right The discharge current ranges from 0 1 to 2 0A To start the process press Start Enter key for m...

Page 14: ...0 1A 2 0A Set the discharge voltage which can be adjusted 3 0V CELL 3 3V CELL Set the voltage and number of cells along with the normal voltage 1 6S Set the charge current which can be adjusted 0 1 10...

Page 15: ...N 120Min User set up starting screen The battery is on the cyclic process of charge and discharge can often become warm after charge or discharge period The program can insert a time delay to occur af...

Page 16: ...re 11 9 set this number as the value for safety timer setting If the charger stopped at this threshold about 140 of the capacity will have been fed into the battery SYSTEM SET UP VARIOUS INFORMATION D...

Page 17: ...TAGE INVALID Voltage of one cell in the battery pack is invalid The external temperature of the unit goes too high EXT TEMP TOO HI OVER CHARGE CAPACITY LIMIT The battery capacity is more than the maxi...

Page 18: ...employ for using operating and maintaining the device For this reason we are obliged to deny all liability for loss damage or costs which are incurred due to the incompetent or incorrect use and oper...

Reviews: