Important Safety Warnings 

Please read these important safety warnings before attempting to install 

or use this product.  

Do not operate the gate motor unless the gates are in full view and free 

from objects such as cars and other obstructions. 

Children must be supervised near the gates at all times, especially 

when the gate motor is in use. 

Ensure that the obstruction sensing function of the gate motor is 

operational and adjusted as necessary. 

Keep hands and any loose clothing well clear of the gate(s) and gate 

motor at all times. 

Before attempting to service the gate motor or removing the cover, turn 

off and / or disconnect the power to the gate motor. If you are unable to 
do this, then we strongly recommend you call an electrician. 

Care 

should be taken as there are moving components inside the gate 
motor that may cause damage or personal injury. 

 

Keep any gate controllers out of reach of children. Any wired or wireless 

controllers must be installed away from any moving parts, and it must 
be at a minimum height of 1.5m from the ground.  

Regularly check that all safety features and safety accessories are fully 

functioning. 

 

Warning

:

 

Failure to comply with these safety warnings or installation instructions 
may result in serious personal injury and/or property damage. 

 

AG5 DC2 GATE MOTOR 

INSTALLATION AND SET UP 

INSTRUCTIONS 

Summary of Contents for AG 5 DC2

Page 1: ...l AG 5 DC2 Single Swing Gate Motor Kit Solar Powered and 12V Low Voltage June 2019 Installation and Set Up Instructions Unit 27 49 Corporate Boulevard Bayswater Vic 3153 Phone 1800 111 930 Email info...

Page 2: ...e attempting to service the gate motor or removing the cover turn off and or disconnect the power to the gate motor If you are unable to do this then we strongly recommend you call an electrician Care...

Page 3: ...e hinge to allow the arms to rotate around during the opening of the gate We recommend 1 5mm twin active lighting cable for power supply wiring and 1mm figure 8 wire for wiring push buttons and other...

Page 4: ...ormer Terminals Push Button Wire in Receiver Terminals Connect wires to OSC and COM PE Beam Terminals Connect wires to PEB and COM 12V Power Out Terminals V positive terminal 0V Negative terminal Moto...

Page 5: ...low the gate drive arm to move by hand Pull the DC motor back towards the gears to engage Ensure the DC motor gear has meshed with the drive gear Fully tighten the Internal Release Bolt and check the...

Page 6: ...he battery Note the polarity Red wire to Red battery terminal Black Blue wire to Black battery terminal The board should now be powered and great care should be taken to avoid shorting out or otherwis...

Page 7: ...for opening the gate and the GREEN LED light is on OR closing the gate and the RED LED light is on Activate the gate motor using the handset remote and check the rotation of the motor drive arm is tu...

Page 8: ...mounting cradle and remove the drive assembly and circuit board from the gate motor mounting cradle Take care not to damage the circuit board or allow it to get wet AG5 DC2 GATE MOTOR INSTALLATION AN...

Page 9: ...post and check that the cradle is level Fit the drive assembly into the cradle Ensure the washers are in place and fully tighten the 4 nuts to firmly secure the drive assembly in the mounting cradle...

Page 10: ...e Ensure the swing arm is at the end of the slot furthest from the gate motor Measure approximately 40mm back towards the gate motor from the marked position and attach the mechanical latch swing arm...

Page 11: ...e the correct cam until it clicks the corresponding limit switch see above Re tighten the cams Engage the Internal Release see page 5 CAUTION The gate will now open close when the gate motor is activa...

Page 12: ...battery be connected first during this stage of the installation The primary power source can be connected after all the necessary set up procedures and adjustments are made Refer to the DC 2 Circuit...

Page 13: ...locate the Motor Force trim pot on the circuit board This adjustment controls the motor torque and obstruction sensing of the gate motor The motor needs to have enough torque force to fully open and c...

Page 14: ...oses then press and hold down the OSC button for 30 seconds and release the button Once time is set flick DIP switch 1 back to OFF To start the Auto Close function flick DIP switch 8 to ON and leave i...

Page 15: ...n to avoid shorting out or otherwise damaging the circuit board Turn on the transformer replace the plastic circuit board cover and metal motor cover and test Terminal Block 12 v Low Voltage Transform...

Page 16: ...over and test Solar Panel Wires RED tipped wire POSITIVE BLACK tipped wire NEGATIVE Terminal Block 1 5mm Twin Active Low Voltage Cable Weather Proof Enclosure Terminal Block from solar regulator Conne...

Page 17: ...cover Attach the wire to the terminals on the push button We suggest to use 0 75mm figure 8 wire for the push button wire Drill a small hole either at the rear of the enclosure or the bottom of the en...

Page 18: ...eakage actions of third parties and other events or accidents outside of G Force Automatic Gate s reasonable control and not arising from normal operating conditions G Force Automatic Gates is not res...

Page 19: ...tighten all terminal block screws and ensure any cables are not frayed at the ends 5 Ensure Receiver is firmly mounted 6 Tighten all mounting and attachment bolts 7 Check screws on Push Button covers...