© 2012 G Force Automatic Gates All Rights Reserved
Battery Connection for Bench Testing
ALWAYS TURN THE POWER OFF AND DISCONNECT THE BATTERY BEFORE MAKING ANY WIRING
CONNECTIONS
Battery Connection
Double piggy back spade
connectors for solar power or single
spade connectors for transformer
power
Pre Installation Set Up and
Testing
AG5 DC2 Gate Motor
We recommend the gate motor settings and direction of rotation be set up and tested prior to
installation. Place the gate motor on a suitable work bench.
Care should be taken as there are moving components inside the gate motor that may
cause damage or personal injury.
Place the battery on the bench next to the motor.
Connect the battery wires to the battery terminals on the battery. Note the polarity (
Red
wire to
Red
battery terminal,
Black / Blue
wire to
Black
battery terminal). The board should now
be powered and great care should be taken to avoid shorting out or otherwise damaging the
circuit board.
Activate the gate motor using one of the handset remote. The remotes are coded to the gate
motor during assembly. Alternatively, refer to the “
Handset Remote Programming”
data sheet to
code in the handset. Press the handset again to stop the motor and press the handset again to
reverse the motor direction. To stop the motor, press the remote handset or disconnect a battery
lead.
Battery wires
Motor Wires
Drive Arm
DC Motor
Circuit Board and Cover
Drive Assembly
Motor Mounting
Cradle
Refer to the “DC 2
Circuit Board”
data sheet included with this manual and locate the battery
wires on the circuit board. Ensure the battery wires are correctly connected to the correct termi-
nals on the circuit board
.