Battery Wires
Connect 12 V Transformer
Wires to 12-24VAC Terminals
ENSURE THE TRANSFORMER IS SWITCHED OFF AND THE BATTERY DISCONNECTED
Refer to the “
DC2 Circuit Board”
data sheet included with this manual and locate the ‘12-
24VAC’ terminals on the circuit board.
Connect the 12 v transformer wires to the ‘12-24VAC’ terminals on the circuit board. There is
no positive or negative transformer wire and they can connect to either of the two “12-24VAC’
terminals. Connect the battery wires to the battery.
Red
, Positive wire to
Red
battery terminal,
Black / Blue
Negative wire to
Black
battery terminal. The board should now be powered
and great care should be taken to avoid shorting out or otherwise damaging the circuit board.
Turn on the transformer, replace the plastic circuit board cover and metal motor cover and test.
Terminal Block
12 v Low Voltage
Transformer Wires
1.5mm Twin Active Low
Voltage Cable
Weather Proof
Enclosure
If the 12 v low voltage transformer wires need to be extended then we recommend you use a
terminal block / joiner. Place the terminal block / joiners into a small enclosure for protection and
outdoor installation.
DC2 Transformer Wiring
Instructions
DIY Automatic Gate Kits
Solar & Low Voltage Specialists
PH 1800 111 930
Red
wire to
Red
battery
terminal
Black / Blue
wire to
Black
battery terminal
Battery Connection
Transformer
12 V
Transformer
Wires
© 2012 G Force Automatic Gates All Rights Reserved
Feed transformer wires through the
hole in the support tray with the
motor wires