background image

 

© 2012 G Force Automatic Gates All Rights Reserved 

GENERAL 

G-Force Automatic Gate products are covered by the manufacturer’s warranty which covers defects in materials and workmanship for 
the Warranty Periods stated below. This warranty is additional to any applicable statutory requirements, subject to the exclusions and 
limitations stated below. 

Product is deemed to be warranted from the date of initial purchase from G-Force Automatic Gates. Proof of purchase is required when 
applying for warranty claims. 

Warranty is offered on a Back-to-Base Warranty basis. Where issues can’t be resolved by your Installer or local Reseller in person, or by 
G-Force Staff over the phone, product will need to be returned at Customer Cost to G-Force’s Repair Centre in Bayswater, VIC for 
assessment, repair or replacement.  

Warranty Periods

 

 

Exclusions & Limitations 

The warranties stated herein do not cover damage, malfunction or service failures caused by: 

Failure to follow G-Force or Product Installation, Operation or Maintenance Instructions 

Repair or modifications to your G-Force product by someone other than a G-Force Service Technician, Authorised Installer or 
Reseller 

Abuse, misuse or negligent acts 

Batteries or Fuses supplied with your G-Force product (inc Handset batteries) 

Power failure surges, lightning, fire, water damage, pest damage, accidental breakage, actions of third parties and other events 
or accidents outside of G-Force Automatic Gate’s reasonable control and not arising from normal operating conditions 

G-Force Automatic Gates is not responsible for any special, incidental, consequential or punitive damages arising from the use 

or 

Warranty & Returns 

POLICY

 

 

1

 

year

 

 

DIY

 

Gate Kits

 

Applicable Kits:

  

FG 5, SW 5, DSW 5, SL2000,

 

1

 

year

 

Accessories

 

Such as:  

Push Buttons, Keypads, PE Beams, .

 

3

 

month

 

Spare Parts 

(exclusive of warranty replacements)

 

Such as: 
Control Boards, Receivers, Remote Controls, Limit 
Switches, DC Motors, etc.

 

1

 

Request  

RMA #

 

To lodge a claim, contact G-Force Automatic Gates on 1800 111 930  

 

2

 

Return Goods 
to G-Force

 

Goods are to be returned to G-Force Automatic Gates at the Customer’s cost. G-Force will assess returned 
product within 7 days to determine the extent of warranty cover and likely repair costs

 

 

 

3

 

Repair or Re-
placement of 
Goods

 

In-Warranty

 Repairs will proceed as soon as practicable. The manufacturer’s offering the warranty 

reserves the right to repair or replace product at its discretion. It may, at its discretion, use new, remanufac-
tured, or refurbished parts or products when repairing or replacing product. Replaced parts become the 
property of G-Force Automatic Gates. Repair costs and return freight of in-warranty repairs will be covered 
free of charge

 

Non-Warranty

 Repairs will not proceed until you are notified of estimated Repair Costs, we receive authori-

sation and payment details from you to proceed. Where product is deemed to be unrepairable, and you re-

Summary of Contents for AG 5 DC2

Page 1: ...l AG 5 DC2 Single Swing Gate Motor Kit Solar Powered and 12V Low Voltage June 2019 Installation and Set Up Instructions Unit 27 49 Corporate Boulevard Bayswater Vic 3153 Phone 1800 111 930 Email info...

Page 2: ...e attempting to service the gate motor or removing the cover turn off and or disconnect the power to the gate motor If you are unable to do this then we strongly recommend you call an electrician Care...

Page 3: ...e hinge to allow the arms to rotate around during the opening of the gate We recommend 1 5mm twin active lighting cable for power supply wiring and 1mm figure 8 wire for wiring push buttons and other...

Page 4: ...ormer Terminals Push Button Wire in Receiver Terminals Connect wires to OSC and COM PE Beam Terminals Connect wires to PEB and COM 12V Power Out Terminals V positive terminal 0V Negative terminal Moto...

Page 5: ...low the gate drive arm to move by hand Pull the DC motor back towards the gears to engage Ensure the DC motor gear has meshed with the drive gear Fully tighten the Internal Release Bolt and check the...

Page 6: ...he battery Note the polarity Red wire to Red battery terminal Black Blue wire to Black battery terminal The board should now be powered and great care should be taken to avoid shorting out or otherwis...

Page 7: ...for opening the gate and the GREEN LED light is on OR closing the gate and the RED LED light is on Activate the gate motor using the handset remote and check the rotation of the motor drive arm is tu...

Page 8: ...mounting cradle and remove the drive assembly and circuit board from the gate motor mounting cradle Take care not to damage the circuit board or allow it to get wet AG5 DC2 GATE MOTOR INSTALLATION AN...

Page 9: ...post and check that the cradle is level Fit the drive assembly into the cradle Ensure the washers are in place and fully tighten the 4 nuts to firmly secure the drive assembly in the mounting cradle...

Page 10: ...e Ensure the swing arm is at the end of the slot furthest from the gate motor Measure approximately 40mm back towards the gate motor from the marked position and attach the mechanical latch swing arm...

Page 11: ...e the correct cam until it clicks the corresponding limit switch see above Re tighten the cams Engage the Internal Release see page 5 CAUTION The gate will now open close when the gate motor is activa...

Page 12: ...battery be connected first during this stage of the installation The primary power source can be connected after all the necessary set up procedures and adjustments are made Refer to the DC 2 Circuit...

Page 13: ...locate the Motor Force trim pot on the circuit board This adjustment controls the motor torque and obstruction sensing of the gate motor The motor needs to have enough torque force to fully open and c...

Page 14: ...oses then press and hold down the OSC button for 30 seconds and release the button Once time is set flick DIP switch 1 back to OFF To start the Auto Close function flick DIP switch 8 to ON and leave i...

Page 15: ...n to avoid shorting out or otherwise damaging the circuit board Turn on the transformer replace the plastic circuit board cover and metal motor cover and test Terminal Block 12 v Low Voltage Transform...

Page 16: ...over and test Solar Panel Wires RED tipped wire POSITIVE BLACK tipped wire NEGATIVE Terminal Block 1 5mm Twin Active Low Voltage Cable Weather Proof Enclosure Terminal Block from solar regulator Conne...

Page 17: ...cover Attach the wire to the terminals on the push button We suggest to use 0 75mm figure 8 wire for the push button wire Drill a small hole either at the rear of the enclosure or the bottom of the en...

Page 18: ...eakage actions of third parties and other events or accidents outside of G Force Automatic Gate s reasonable control and not arising from normal operating conditions G Force Automatic Gates is not res...

Page 19: ...tighten all terminal block screws and ensure any cables are not frayed at the ends 5 Ensure Receiver is firmly mounted 6 Tighten all mounting and attachment bolts 7 Check screws on Push Button covers...

Reviews: