5. INSTALLATION AND INITIAL SETTINGS
5-9
Connection via the FI-5002 junction box (option)
The FI-5002 has two terminal resistors (R1 and R2). The resistors are set in the
following manner:
• When no backbone cable is connected, R1 and R2 are set to ON position.
• When one backbone cable is connected, either R1 or R2 is set to ON position.
• When two backbone cables are connected, R1 and R2 are set to OFF position.
5.3
Input/Output PGNs
The FI-70 can input/output the following PGNs.
Input PGNs
PGN
Description
PGN
Description
059904
ISO Request
129285
Navigation - Route/WP Information
060928
ISO Address Claim
129538
GNSS Control Status
061184
Self Test Group Function
129539
GNSS DOPs
126208
NMEA - Request/Acknowledge
Group Function
129794
AIS Class A Static and Voyage
Related Data
126992
System Time
129809
AIS Class B “CS” Static Data Report,
Part A
126996
Product Information
129810
AIS Class B “CS” Static Data
Report, Part B
127237
Heading/Track Control
130306
Wind Data
127245
Rudder
130310
Environmental Parameters
127250
Vessel Heading
130311
Environmental Parameters
127251
Rate of Turn
130312
Temperature
127252
Heave
130313
Humidity
127257
Attitude
130314
Actual Pressure
127258
Magnetic Variation
130316
Temperature, Extended Range
127488
Engine Parameters, Rapid Update
130576
Trim Tab Status
127489
Engine Parameters, Dynamic
130577
Direction Data
127493
Transmission Parameters, Dynamic
130578
Vessel Speed Components
127497
Trip Parameters, Engine
128267
Water Depth
127505
Fluid Level
065280
Proprietary PGN (Furuno)
128259
Speed, Water Referenced
130816
Proprietary PGN (Furuno)
129025
Position, Rapid Update
130818
Proprietary PGN (Furuno)
128267
Water Depth
130821
Proprietary PGN (Furuno)
129026
COG & SOG, Rapid Update
130822
Proprietary PGN (Furuno)
129029
GNSS Position Data
130825
Proprietary PGN (Furuno)
129033
Local Time Offset
130841
Proprietary PGN (Furuno)
129038
AIS Class A Position Report
130822
Proprietary PGN (Furuno)
CN1
CN1
CN3
CN3 CN4
CN4 CN5
CN5 CN2
CN2
R2
R1
CN3
CN4
CN5
CN2
CN2
: Resistor is
disconnected. (OFF)
: Resistor is
connected. (ON)
Jumper block settings
Summary of Contents for FI-70
Page 1: ...FI 70 OPERATOR S MANUAL www furuno com Model COLOR INSTRUMENT...
Page 10: ...EQUIPMENT LISTS viii This page is intentionally left blank...
Page 18: ...1 OPERATION AND CONTROLS OVERVIEW 1 8 This page is intentionally left blank...
Page 44: ...3 ALARMS 3 10 This page is intentionally left blank...
Page 62: ...4 SYSTEM MENU 4 18 This page is intentionally left blank...
Page 76: ...5 INSTALLATION AND INITIAL SETTINGS 5 14 This page is intentionally left blank...
Page 90: ...24 Apr 2017 H MAKI D 1...
Page 91: ...24 Apr 2017 H MAKI D 2...
Page 98: ......