3-1
3.
ADJUSTMENTS
3.1
Measuring TX Output
1. Set the controls of the control unit as follows.
2. Connect the oscilloscope across Vout + and Vout – jacks on the TAMP boards
(10P6624) and measure the peak-to-peak voltage of the TX signal at the center
point of its pulse length.
Measuring TX output signal
TX OUTPUT: 10 (Max.)
PULSE LENGTH: 10 (Max.)
VER BEAMWIDTH: NARROW
RANGE: 200 m
WARNING
WARNING
Do not open the equipment unless
totally familiar with electrical circuits
and service manual.
Only qualified personnels are allowed to
work inside the equipment.
ELECTRICAL SHOCK HAZARD
Waveform measured across Vout + and Vout -
Channel No.
Test Point Location
1.0 ms/division, 200 V/division
5.0 μs/division, 100 V/division
5
3
1
6
4
2
7
9
11
8
10
12
TP8
TP7
TP1
TP2
(V. DC)
(GND)
(V out + )
(V out - )
TP1
TP2
(V out + )
(V out - )
TP1
TP2
(V out + )
(V out - )
TP1
TP2
(V out + )
(V out - )
Summary of Contents for CSH-5LMARK-2
Page 8: ...EQUIPMENT LISTS vi This page is intentionally left blank ...
Page 26: ...1 MOUNTING 1 18 This page is intentionally left blank ...
Page 54: ...3 ADJUSTMENTS 3 8 This page is intentionally left blank ...
Page 60: ...AP 6 ...
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ...This page intentionally left blank ...
Page 67: ......
Page 68: ...8 May 2013 H MAKI D 2 ...
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ...D 9 ...
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ...D 18 ...
Page 85: ......
Page 86: ......