Error Messages
Error Description
Cause of the error
Action
OVER TEMP.
The temperature
exceeds the set value
while heating.
Defect in the heating
system.
Contact service
center.
VISUAL ERROR
The image process
cannot focus on the
fiber, find the clad
line, or find the core
line while inspecting.
Fiber is dirty.
Retry the splice from
preparation. Make
sure to clean the bare
portion of the fiber.
Inappropriate fiber
program is selected.
Check and correct the
program.
Incorrect parameter
setting for FOCUS.
Check and correct the
parameters.
Defect in the image
processing system.
Contact service
center.
Defect in the
screening system.
Contact service
center.
Optics is dirty.
See Maintenance
chapter.
OUT OF SPEC
The fiber is out of
applicable range.
Inappropriate fiber
program is selected.
Check and correct the
program.
Cladding diameter is
out of applicable
range.
Can not splice with
S178 Ver.2.
FOCUSING ERROR
Unable to focus on
the fiber.
Fiber is dirty.
Retry the splice from
preparation. Make
sure to clean the bare
portion of the fiber.
Inappropriate fiber
program is selected.
Check and correct the
program.
Incorrect parameter
setting for FOCUS
and FIELD.
Check and correct the
parameters.
Defect in the image
processing system.
Contact service
center.
Optics is dirty.
See Maintenance
chapter.
LOW BATTERY
Battery has no power
remaining.
Battery has no power
remaining.
See
“Recharging
Battery
”.
(*)
The Heater consumes a lot of electric power to shrink the protection sleeve fast. Therefore, the battery output voltage descends.
In the battery that repeats 300-times electrical charge and discharges or more, the voltage descent under heating is large. When
the voltage decent of the battery is large, the heating time is long, and the heater error 17 or the heater error 27 might be
displayed. If the battery is charged full and the same error message is displayed, the battery might be
weakening. Please use