Programming Guide
8-21
8.5.2.
Counter
1.
Select a Setting item in the “Counter“ list and press Enter key.
2. Pop-up window shows available functions. Press
▲
▼
keys to select
desired function and press Enter key.
3. Pop-up window shows available setting. Press
▲
▼
keys to select desired
setting and press Enter key.
4. Press Escape key and a pop-up window prompts the operator to confirm the
change. Select “Over write” to confirm the change, or “Cancel” to cancel the
operation and press Enter.
5. Repeatedly press Escape key until the Ready screen is displayed.
Available settings for each Item
Setting Title
Functions
Counter Reset
Alarm On/Off
Alarm Count
Arc
Cleaving
Stripping
Splicing
Do not Reset
Reset
Off
On
Displaying the current count can be
adjusted to any count. Select a digit
with ◄ ► and press
▲
▼
to
increase/decrease the value. When
“+ “ is selected, press
▲
key to
advance to 32767 or press
▼
key to
advance to 0
Total Arc
Not Available
8.5.3.
Data
1.
Select “Before Splicing” or “After Splicing” in the “Data“ list and press Enter key.
2. Pop-up window shows available setting menus. Press
▲
▼
keys to select
desired setting and press Enter key.
3. Pop-up window shows
“On/Off”. Press
▲
▼
keys to select desired setting and
press Set key.
4. Press Escape key and a pop-up window will prompt the operator to confirm the
change. Select “Over write” to confirm the change, or “Cancel” to cancel the
operation and press Enter.
5. Repeatedly press Escape key until the Ready screen is displayed.
Data which can be displayed
Process for Data Display
Data
Before Splice
Cleave Angle
Clad Offset
Core Offset
Attenuation Loss
After Splice
Cleave Angle
Clad Offset
Core Offset
Estimation Loss
Detailed Loss
Splice Result Icon
(
When “Estimamation Loss” is "On", it is active.)
“Data Output” in the “Parameter” must be “Active” to display the data.