Fusion Splicing
6-3
When charging battery with the external charger
Follow the procedure below to charge the S943B battery.
1. Place the S958C Charger on a flat surface and connect to AC power source with AC adapter. When a power
supply is connected, the power lamp turns on green steady light.
2. Insert the S943B battery to charge slot on the S958C charger. 2 batteries can be inserted in the S958C
charger. The S958C charger charges with two batteries at the same time.
3. The red light on the S958C charger illuminates while recharging. It takes approximately 2 hours to recharge
an empty battery.
4. The light changes to green when the recharge is completed. Remove the S943B battery.
5. Disconnect the S958C charger from AC power source.
S943B battery is lithium ion type rechargeable battery; it can be recharged at any time,
regardless if it is fully empty or still with some residual power.
If storing battery for a long time, the power level becomes very low caused by
self-discharging and the battery may be degraded. Be sure to recharge the battery at least
every 2 months even when not in use.
It is possible that the battery could not be fully charged, if moving the battery from a cold
place (<5°C) to a warm place (around 20°C) and then immediately charging it. In this
case, make sure battery is in the new environment for a short while to equalize the
temperature, then charge the battery.
When charging battery, the room temperature must be in the range of 5 - 40°C.
6.1.5.
Turn Splicer ON and OFF
Turning ON/OFF the power : Keep pushing power key (for about 2 seconds)
Turning ON power
The opening massage will appear on the LCD screen for a short while, before the ready screen showing up.
Turning OFF power
The LCD screen is turned off.
The power supply cuts after all
motors perform the reset operation.
Power key