Programming Guide
8-8
Parameter Table for Heater Program
Parameter name
Min Max
Description
1
st
Heat Temp IN [deg.C]
0
280 Temperature of INNER heater for the first half.
1
st
Heat Temp OUT [deg.C]
0
280 Temperature of OUTER heater for the first half.
1
st
Heat Time [sec]
0
300 Operation time of the first half.
2
nd
Heat Temp IN [deg.C]
0
280 Temperature of INNER heater for The latter half.
2
nd
Heat Temp OUT [deg.C]
0
280
Temperature of OUTER heater for The latter
half.
2
nd
Heat Time [sec]
0
300 Heating time after 1
st
heating
Cool Temp [deg.C]
0
280 Temperature to arrive at end of cooling process.
Pre Heat Temp IN [deg.C]
0
280
Temperature of INNER heater for preliminary
heating.
Preliminary heating temperature before the first
half.
Pre Heat Temp OUT [deg.C] 0
280
Temperature of OUTER heater for preliminary
heating.
Preliminary heating temperature before the first
half.
Pre Heat Time [sec]
0
300
Operation time of preliminary heating after the
end of cooling process or before the first half.
Auto Start
0
2
Setting for automatic start function.
[0] : The non-operation. Manual start operation.
[1]]: The operation. When fiber set and left
clamping
is
shut,
the
heating
start
automatically.*)
[2]:
The
operation.
Consecutive
heating
operation.
Compensation Auto Start
0
30 Expansion time of the automatic operation.
* Do not leave the protection sleeve in a heater after finish of shrinkage. There is the case that coating
melts.
Time chart of heater parameters
INNER Heater
OUTER Heater
1
st
Heat Temp. IN
1
st
Heat Temp. OUT
2
nd
Heat Temp. IN
2
nd
Heat Temp. OUT
Pre Heat Temp. IN
Pre Heat Temp. OUT
2
nd
Heat Time
1
st
Heat Time
Pre Heat Time
Temperature
Time
Cool Temp.