Fusion Splicing
7-4
7.1.5.
Splicing Defects
Defect
Possible Causes
Action
Bubbling
Wrong fiber type selected
Select the correct Fusion Program, and
repeat fusion splicing.
Faulty cleave
Repeat fiber preparation and fusion splicing.
Dirty fiber end
Repeat fiber preparation and fusion splicing.
Degradation of electrodes
Replace the electrodes.
Not spliced
or
Neck-down
Wrong Fusion Program
selected
Select the correct Fusion Program, and
repeat fusion splicing.
Faulty cleave
Repeat fiber preparation and fusion splicing.
Excessive arc current
Perform an arc check, and adjust arc power.
Insufficient fiber feed
Adjust the fiber feed amount.
Degradation of electrodes
Replace the electrodes.
Thickening
Wrong Fusion Program
selected
Select the correct Fusion Program, and
repeat fusion splicing.
Excessive fiber feed
Adjust the fiber feed amount.
Degradation of electrodes
Replace electrodes.
Excessive arc current
Perform an arc check, and adjust arc power.
Streak
Wrong Fusion Program
selected
Select the correct Fusion Program, and
repeat fusion splicing.
Degradation of electrodes
Replace the electrodes.
Weak arc
Perform an arc check and adjust arc power,
or apply an additional arc.
7.1.6.
Removing the Spliced Fiber
1. Raise both heater clamps before removing the fiber.
2. Open the windshield. A tension test (200 g) is performed on the fibers.
3. Buzzer beeps once when the tension test is completed.
4. Remove the spliced fiber, pulling slightly so that the fiber is taut.
Handle the spliced fiber carefully. Do not twist the fiber.
!
CAUTION
Do not attempt to load fibers while the S178 Ver.2 fusion splicer is
resetting. Load the fibers only after the reset operation is complete and
the READY screen is displayed.