2-26
SPARC Enterprise M8000/M9000 Servers Service Manual • October 2012
2.5.2.2
Checking the Firmware Configuration
Login authority is required to check the firmware configuration. The following procedure for
these checks can be made from the maintenance terminal:.
1. Log in to the XSCF.
2. Execute the
version
command.
The
version
command will print the firmware version information to the screen. For
the detailed procedure, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000
Servers XSCF User’s Guide
.
2.5.3
Downloading the Error Log Information
If you want to download the error log information, use the XSCF log fetch function. The
XSCF Unit has an interface with external units so that a service engineer can easily obtain
useful maintenance information such as error logs
Connect the maintenance terminal, and use the CLI or BUI to issue a download instruction to
the maintenance terminal to download Error Log information over the XSCF-LAN.
Note –
When the XSCF unit has a redundant configuration, log in also to the standby XSCF
and obtain the log file in the same manner.
2.6
Error Conditions
This section describes error conditions and relevant corrective actions.
This work is explained in the following sections:
■
Section 2.6.1, “Predictive Self-Healing Tools” on page 2-27
■
Section 2.6.2, “Monitoring Output” on page 2-28
■
Section 2.6.3, “Messaging Output” on page 2-30
Details of the fault information, see the
SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide
.
See the Oracle Solaris 10 documentation for more information on predictive self-healing.
XSCF>
version
Summary of Contents for SPARC Enterprise M8000
Page 4: ......
Page 15: ...Contents xv Index Index 1 ...
Page 16: ...xvi SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 22: ......
Page 27: ...Chapter 1 Safety and Tools 1 5 M9000 Server Front View ...
Page 29: ...Chapter 1 Safety and Tools 1 7 Power Supply Unit PSU ...
Page 38: ...1 16 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 88: ...2 50 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 148: ......
Page 154: ...5 6 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 205: ...Chapter 7 I O Unit IOU Replacement 7 13 FIGURE 7 8 Removing the IOU Front of M9000 1 1 2 3 ...
Page 227: ...Chapter 8 FAN Unit Replacement 8 11 FIGURE 8 9 Removing the FAN Unit Rear of M8000 1 2 ...
Page 256: ...10 8 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 272: ...11 16 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 312: ...13 30 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 340: ...15 14 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 358: ...17 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 370: ...18 12 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 380: ...19 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 409: ...Chapter 20 Backplane Replacement 20 29 FIGURE 20 16 Removing the FANBP Rear of the M8000 ...
Page 422: ...21 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 439: ...Chapter 23 Switch Backplane Replacement 23 7 FIGURE 23 4 Removing the SWBP Rear of the M8000 ...
Page 442: ...23 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 460: ...24 18 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 484: ...25 24 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 494: ...A 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 544: ...C 4 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 552: ...D 8 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...