PRIMERGY TX300 S4 User's Guide
Event logs
Following event logs are stored at team configuration (Source: iANSMiniport).
table: Event logs
ID
Type
Message
Remarks
3
Error
The necessary registry parameter could not be read.
To resolve this problem, delete the adapter team, and
create a new team.
Even if a team is created successfully,
this error log may be stored during a
system startup. Ignore the log since
there is no problem.
6
Information
The primary adapter has been initialized: (Adapter
name)
Even if a team is created successfully,
these logs are stored during a system
startup. Ignore the logs since there is
no problem.
7
Information
The adapter has been initialized: (Adapter name)
8
Information
(Team name): The team has been initialized.
10 Information The current primary adapter is changed from the next
adapter: (Adapter name)
After a team is configured, these logs
may be stored many times in the
system log on the Event Viewer
during a system startup. Ignore the
logs since there is no problem.
The logs may not be stored when
[Link Standby] is enabled in
[Advanced Settings] of the LAN
adapter.
11
Warning
The next adapter link is not connected: (Adapter
name)
12 Information The secondary adapter has a priority: (Adapter name)
13 Warning
(Adapter name) has been disabled with a team.
14 Information The secondary adapter has been added to a team
again: (Adapter name)
15 Information The next adapter link is connected: (Adapter name)
16 Warning
(Team name): The last adapter has been unlinked.
Network connection has failed.
17 Information (Team name): The adapter has established a link
again. The network connection has been recovered.
18 Information The primary adapter at the next priority level has been
detected: (Adapter name)
19 Information The secondary adapter at the next priority level has
been detected: (Adapter name)
20 Information The primary adapter at the next priority level is
preferentially handled: (Adapter name)
21 Information The secondary adapter at the next priority level is
preferentially handled: (Adapter name)
22 Warning
The primary adapter could not detect the next probe:
(Adapter name) Cause: The team may be divided into
groups.
35 Warning
(Team name) without one adapter is initialized.
Confirm that all adapters exist and function.
38 Information (Adapter name) has been deleted from the team.
42 Warning
(Adapter name) is not specified properly. The adapter
cannot process the remote management function while
being a network team.
This log may be stored even if the
remote management function is not
used on the onboard LAN. When not
using the remote management
function, ignore the log since there is
no problem.