80
Operating Manual
TX100 S2 Core Edition
Troubleshooting and tips
7.2
Incorrect date and time
Ê
Set the date and time in the operating system.
If the date and time are still wrong after the server has been switched off and
back on again, replace the lithium battery (for a description refer to the
Technical Manual for the D2779 system board) or contact the Fujitsu
Technology Solutions customer service team.
7.3
Added drive reported as defective
The RAID controller is not configured for this drive.
Ê
Use the preinstalled ServerView RAID Manager to reconfigure your RAID
controller.
For further information, please refer to the "ServerView Suite RAID
Management" user guide available on your ServerView Suite DVD 2 or from
the Fujitsu Technology Solutions manuals server at
http://manuals.ts.fujitsu.com
. Point to
Industry Standard Servers
-
Software
-
ServerView Suite
-
Administration and Manageability
-
RAID Management
.
I
Replace the hard disk drive if it continues to be reported as defective
(see the "PRIMERGY TX100 S2 Options Guide").