manualshive.com logo in svg
background image

 http://www.supermicro.com

MNL-xxxx- QRG

Board Layout

SuperStorage L-Serie Quick Reference Guide

Rear View

CPU Installation 

Beep Codes

LED Indicator

Heatsink Installation 

1. Place heatsink on top of installed CPU

2. Line up the four screws to socket

3. Push down heatsink and screw down as shown 

    (cross pattern, in order: A, C, B, D)

4. NOTE: Only use 6-8 lb/f of torque; otherwise, hand-tighten 

    each screw, to avoid damaging the system

MEMORY

Caution

Top View of DDR3 Slot

Release Tab

Release Tab

Note: Notch should align 

with  the  receptive  key 

point on the slot.  

Notch

Notch

Front View

Align CPU to socket; 

install CPU straight down

         NOTE: 

Do not bend pin inside socket

!

FAN5

T-SGPIO2

JSD1

JBT1

JD1

CPU1

CPU2

CPU2

CPU1

CPU2

CPU1

P2-DIMME1

P2-DIMMF2

P2-DIMMF1

P2-DIMMG2 P2-DIMMG1

P2-DIMMH2 P2-DIMMH1

P1-DIMMA2 P1-DIMMA1

P1-DIMMB2 P1-DIMMB1

P1-DIMMC1 P1-DIMMC2 P1-DIMMD1 P1-DIMMD2

SLOT1 PCI-E 3.0 X8

SLOT2 PCI-E 3.0 X8

SLOT3 PCI-E 3.0 X8

SLOT4 PCI-E 3.0 X8

SLOT5 PCI-E 3.0 X8

CMOS CLEAR

SLOT6 PCI-E 3.0 X8

SP1

CPU2

CPU2

CPU2

JPW1

P2-DIMME2

JPW3

L-SAS4~7

L-SAS0~3

Intel 

PCH

JPS1

CPU1

X9DRD-7JLN4F

Description

No.

1

2

3

4

5

8

7

JBOD Expansion Port

CPU1 Slot2 PCI-E 3.0 x8

CPU2 Slot3 PCI-E 3.0 x8

CPU2 Slot4 PCI-E 3.0 x8

CPU2 Slot5 PCI-E 3.0 x8

CPU1 Slot6 PCI-E 3.0 x8

P1-DIMMA1(Blue)/P1-DIMMA2 slot

P1-DIMMB1 (Blue)/P1-DIMMB2 slot 

P1-DIMMC1 (Blue)/P1-DIMMC2 slot

P1-DIMMD1 (Blue)/P1-DIMMD2 slot

P2-DIMME1 (Blue)/P2-DIMME2 slot

P2-DIMMF1 (Blue)/P2-DIMM F2 slot

P2-DIMMG1 (Blue)/P2-DIMM G2 slot

P2-DIMMH1 (Blue)/P2-DIMM H2 slot

CPU1 / P1 install first / minimum requirement

CPU2 

SATA 3  Ports 0~1 (from Intel PCH)

SATA 2 Ports 2~5 (from Intel PCH)

SAS 2.0 ports 0~3, 4~7 (from LSI SAS 2308 Controller) 

JBT1 = CMOS Reset

SATA DOM Power 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

6

9

10

15

11 12

14 13

16

19

18

21

20

17

          SAFETY INFORMATION

IMPORTANT: See installation instructions and safety warning 

before  connecting system to power supply.

http://www.supermicro.com/about/policies/safety_information.cfm

          WARNING:

 

To reduce risk of electric shock/damage to equipment, 

disconnect power from server by disconnecting all power 

cords from electrical outlets.

If any CPU socket empty, install protective plastic CPU cap

          CAUTION:

 

Always be sure all power supplies for this system have

the same power output. If mixed power supplies are 

installed, the system will not operate.

For more information go to : 

http://www.supermicro.com/support

!

!

!

Normal Operation

Drive Failure

Rebuilding to Drive

Drive Assigned as a Hot Spare

Slot Identify command 

has been issued from controller

Indication

LED State

OFF

Solid ON

Slow Blink (1 Hz)

2 Fast Blink, Pause (repeats)

Fast Blink (4 Hz)

Description

No.

3.5” Drive Module

2.5” Drive Module

Blue/Activity

Red/Status

Drive RED LED Indicator

3

1

5

4

7

6

2

1

2

3

4

5

6

7

COM Port1

Dedicated IPMI LAN

USB 0/1/2/3 Ports

LAN 1/2/3/4 Ports

VGA Port

UID Button

Dual JBOD Expansion port

*

*

SSG-6027R-E1R12L features a single expansion port

BIOS Beep Codes

Beep Code/LED

 Message  Description

1 beep

Refresh

Circuits have been reset. 

(Ready to power up)

5 short beeps + 1 long 

beep

Memory

5 long beeps + 2 short 

beeps

Display memory 

read/write status

Video adapter missing or with 

faulty memory

1 continuous beep

System    System overheat

No  memory  detected 

DIMM Module Population Tables

Processors and their Corresponding Memory Slots

t

o

l

S

 

y

r

o

m

e

M

 

g

n

i

d

n

o

p

s

e

r

r

o

C

#

U

P

C

CPU 1 (P1-)

A1

B1

C1

D1

A2

B2

C2

D2

A3

B3

C3

D3

CPU2 (P2-)

E1

F1

G1

H1

E2

F2

G2

H2

E3

F3

G3

H3

Processor and Memory Module Population

Number of

CPUs+DIMMs

CPU and Memory Population Confi guration Table

(For memory to work properly, please install DIMMs as shown below.) 

1 CPU &

3 DIMMs 

CPU1

P1-A1/P1-B1/P1-C1

1 CPU &

6 DIMMs 

CPU1

P1-A1/P1-B1/P1-C1/P1-D1/P1-A2/P1-B2

1 CPU &

9 DIMMs 

CPU1

P1-A1/P1-B1/P1-C1/P1-D1/P1-A2/P1-B2/P1-C2/P1-D2/P1-A3

1 CPU &

12 DIMMs

CPU1

P1-A1/P1-B1/P1-C1/P1-D1/P1-A2/P1-B2/P1-C2/P1-D2/P1-A3/P1-B3/P1-C3/P1-D3

2 CPUs &

6 DIMMs 

CPU1 + CPU2

P1-A1/P1-B1/P1-C1

P2-E1/P2-F1/P2-G1

2 CPUs &

12 DIMMs 

CPU1 + CPU2

P1-A1/P1-B1/P1-C1/P1-D1/P1-A2/P1-B2

P2-E1/P2-F1/P2-G1/P2-H1/P2-E2/P2-F2

2 CPUs &

16 DIMMs 

CPU1 + CPU2

P1-A1/P1-B1/P1-C1/P1-D1/P1-A2/P1-B2/P1-C2/P1-D2

P2-E1/P2-F1/P2-G1/P2-H1/P2-E2/P2-F2/P2-G2/P2-H2

2 CPUs &

18 DIMMs

CPU1 + CPU2

P1-A1/P1-B1/P1-C1/P1-D1/P1-A2/P1-B2/P1-C2/P1-D2/P1-A3

P2-E1/P2-F1/P2-G1/P2-H1/P2-E2/P2-F2/P2-G2/P2-H2/P2-E3

2 CPUs &

24 DIMMs

CPU1/CPU2

P1-A1/P1-B1/P1-C1/P1-D1/P1-A2/P1-B2/P1-C2/P1-D2/P1-A3/P1-B3/P1-C3/P1-D3

P2-E1/P2-F1/P2-G1/P2-H1/P2-E2/P2-F2/P2-G2/P2-H2/P2-E3/P2-F3/P2-G3/P2-H3

Screw #B

Screw #D

Screw #A

Screw #C

Chassis Front Panel LED Indicator Definition

Solid Green/Power is On

Flash Green/Onboard SAS/SATA Drive Activity

Flash Green/Network Connectivity

Flash Green/Network Connectivity

Flash Red/Fan Failure; Solid Red/Over Temperature

Flash Red/Power Supply Failure

State/Indication

Component

Power

Onboard SATA

LAN1

LAN2

Temperature/Fan

Power Failure

Please refer to the user manual for more details on memory types, speeds and configurations