RX4770 M1
Upgrade and Maintenance Manual
77
Basic software procedures
5.2.10 Verifying the system time settings
I
This task only applies to Linux environments.
After the system board has been replaced, the system time is set automatically.
By default, the RTC (Real Time Clock) time standard is set as the local time.
If a Linux OS is used and the hardware clock has been configured as UTC
(Universal Time, Coordinated) in the operating system, the BMC local time may
not be mapped correctly.
Ê
After replacing the system board, ask the system administrator whether the
RTC or UTC time standard is to be used as system time.
I
If the system time (RTC) is set to UTC, the SEL (System Event Log)
time stamps may differ from the local time.
Ê
Enter the BIOS.
Ê
Select the
Main
menu.
Ê
Under
System Time
and
System Date
specify the correct time and date.
I
By default, the system time set in the BIOS is RTC (Real Time Clock)
local time. If your IT infrastructure relies on universally accepted time
standards, set the
System Time
to UTC (Universal Time, Coordinated)
instead. Greenwich Mean Time (GMT) can be considered equivalent
to UTC.
Ê
Save your changes and exit the BIOS.
I
For detailed information on how to access the BIOS and modify settings,
refer to the corresponding BIOS Setup Utility reference manual
5.2.11 Viewing and clearing the System Event Log (SEL)
5.2.11.1 Viewing the SEL
You can view the System Event Log (SEL) using the ServerView Operations
Manager or the ServerView iRMC web frontend:
Viewing the SEL in ServerView Operations Manager
Ê
In ServerView Operations Manager
Single System View
select
Maintenance
from the
Information / Operation
menu.
Summary of Contents for Primergy RX4770 M1
Page 18: ...18 Upgrade and Maintenance Manual RX4770 M1 Contents ...
Page 88: ...88 Upgrade and Maintenance Manual RX4770 M1 Basic software procedures ...
Page 122: ...122 Upgrade and Maintenance Manual RX4770 M1 Hard disk drives solid state drives ...
Page 200: ...200 Upgrade and Maintenance Manual RX4770 M1 Expansion cards and backup units ...
Page 258: ...258 Upgrade and Maintenance Manual RX4770 M1 Processors ...
Page 310: ...310 Upgrade and Maintenance Manual RX4770 M1 System board and components ...
Page 314: ...314 Upgrade and Maintenance Manual RX4770 M1 Cables ...
Page 332: ...332 Upgrade and Maintenance Manual RX4770 M1 Appendix ...