Hard disk drives / solid state drives
7.5
Removing a 2.5-inch HDD / SSD dummy
module
Figure 28: Removing a 2.5-inch dummy module
I
Dummy modules have been installed into unused HDD / SSD bays.
Before installing an additional HDD / SSD, the dummy module needs to
be removed from the desired drive bay.
Ê
Press in on the locking clips on left side of the dummy module to disengage
the locking mechanism (1).
Ê
While keeping the locking clip pressed, pull the dummy module out of its bay
(2).
V
CAUTION!
Save the dummy module for future use.
Always replace dummy modules into unused HDD / SSD bays to
comply with applicable EMC regulations and satisfy cooling
requirements.