258
Upgrade and Maintenance Manual
RX2520
M4
Processor (CPU)
11.3
Replacing a CPU or heat sink
V
CAUTION!
CPUs are modules which are extremely sensitive to electrostatic
discharges and therefore must always be handled with care. After a CPU
has been removed from its protective sleeve or from its socket, place it
with its smooth side down on a non-conducting, antistatic surface. Never
push a CPU over a surface.
11.3.1 Preliminary steps
Ê
"Locating the defective server" on page 45
Ê
"Suspending BitLocker functionality" on page 67
Ê
"Shutting down the server" on page 48
Ê
"Disconnecting the power cord" on page 49
Ê
"Getting access to the component" on page 50
Ê
"Removing the air duct" on page 61
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Software: 5 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Summary of Contents for PRIMERGY RX2520 M4
Page 6: ...6 Upgrade and Maintenance Manual RX2520 M4 ...
Page 22: ...Upgrade and Maintenance Manual RX2520 M4 Content ...
Page 98: ...98 Upgrade and Maintenance Manual RX2520 M4 Basic software procedures ...
Page 118: ...118 Upgrade and Maintenance Manual RX2520 M4 Power supply unit PSU ...
Page 194: ...194 Upgrade and Maintenance Manual RX2520 M4 Fans ...
Page 232: ...232 Upgrade and Maintenance Manual RX2520 M4 Expansion cards and backup units ...
Page 310: ...310 Upgrade and Maintenance Manual RX2520 M4 Accessible drives ...
Page 338: ...338 Upgrade and Maintenance Manual RX2520 M4 Front panel ...
Page 410: ...410 Upgrade and Maintenance Manual RX2520 M4 Appendix A ...
Page 412: ...412 Upgrade and Maintenance Manual RX2520 M4 Appendix B ...
Page 451: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...