
RX2520 M4
Upgrade and Maintenance Manual
251
Processor (CPU)
11.2
Upgrading to 2 CPUs configuration
V
CAUTION!
– CPUs are modules which are extremely sensitive to electrostatic
discharges and therefore must always be handled with care. After a
CPU has been removed from its protective sleeve or from its socket,
place it with its smooth side down on a non-conducting, antistatic
surface. Never push a CPU over a surface.
– Only CPUs of the same type may be used on the system board. That
means the number of the internal CPU cores as well as the primary
clock and the QPI frequency have to be the same.
– For dual operation, use a suitable multiprocessor operating system.
11.2.1 Preliminary steps
Ê
"Suspending BitLocker functionality" on page 67
Ê
"Shutting down the server" on page 48
Ê
"Disconnecting the power cord" on page 49
Ê
"Getting access to the component" on page 50
Ê
"Removing the air duct" on page 61
Upgrade and Repair Unit
(URU)
Hardware: 15 minutes
Software: 5 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Summary of Contents for PRIMERGY RX2520 M4
Page 6: ...6 Upgrade and Maintenance Manual RX2520 M4 ...
Page 22: ...Upgrade and Maintenance Manual RX2520 M4 Content ...
Page 98: ...98 Upgrade and Maintenance Manual RX2520 M4 Basic software procedures ...
Page 118: ...118 Upgrade and Maintenance Manual RX2520 M4 Power supply unit PSU ...
Page 194: ...194 Upgrade and Maintenance Manual RX2520 M4 Fans ...
Page 232: ...232 Upgrade and Maintenance Manual RX2520 M4 Expansion cards and backup units ...
Page 310: ...310 Upgrade and Maintenance Manual RX2520 M4 Accessible drives ...
Page 338: ...338 Upgrade and Maintenance Manual RX2520 M4 Front panel ...
Page 410: ...410 Upgrade and Maintenance Manual RX2520 M4 Appendix A ...
Page 412: ...412 Upgrade and Maintenance Manual RX2520 M4 Appendix B ...
Page 451: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...