394
Upgrade and Maintenance Manual
RX2520
M4
Appendix A
Indicator
Status
Description
A - Identification
blue on
The server has been highlighted using
ServerView Operations Manager, iRMC web
interface or the ID button on the front panel
for easy identification.
blue flashing
The server has been highlighted for easy
identification using the iRMC (AVR) with
disabled local VGA output.
B - CSS
(Customer Self
Service)
off
No critical event detected (CSS component).
orange on
Prefailure event detected (CSS component).
orange flashing CSS component failure detected.
C - GEL
(Global Error
LED)
off
No critical event detected (non CSS
component).
orange on
Prefailure event detected (non CSS
component).
orange flashing
Non CSS component failure detected.
Possible causes:
– System is out of the specified
temperature range
– Defective sensor
– CPU error
– Error detected by server management
software
F - Controller
off
Controller okay
orange on
Controller failure (PCI card installed on
riser card)
G - CPU
off
CPU okay
orange on
CPU failure
H - Memory
off
Memory module running
orange on
Memory module failure
I - iRMC
off
iRMC S5 inactive
green flashing
iRMC S5 okay
K - System fan
off
System fan running
orange on
System fan failure
L - Battery
orange on
Battery failure
Summary of Contents for PRIMERGY RX2520 M4
Page 6: ...6 Upgrade and Maintenance Manual RX2520 M4 ...
Page 22: ...Upgrade and Maintenance Manual RX2520 M4 Content ...
Page 98: ...98 Upgrade and Maintenance Manual RX2520 M4 Basic software procedures ...
Page 118: ...118 Upgrade and Maintenance Manual RX2520 M4 Power supply unit PSU ...
Page 194: ...194 Upgrade and Maintenance Manual RX2520 M4 Fans ...
Page 232: ...232 Upgrade and Maintenance Manual RX2520 M4 Expansion cards and backup units ...
Page 310: ...310 Upgrade and Maintenance Manual RX2520 M4 Accessible drives ...
Page 338: ...338 Upgrade and Maintenance Manual RX2520 M4 Front panel ...
Page 410: ...410 Upgrade and Maintenance Manual RX2520 M4 Appendix A ...
Page 412: ...412 Upgrade and Maintenance Manual RX2520 M4 Appendix B ...
Page 451: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...