46
Upgrade and Maintenance Manual
RX2520
M4
Basic hardware procedures
Ê
When using ServerView Operations Manager to toggle the ID indicator,
choose
Single System View
and press the
Locate
button.
Ê
Remember to switch off the ID indicator after the maintenance task has been
concluded successfully.
4.1.2
Determining the error class
The Local Service Concept (LSC) allows you to identify defective server
components. Failure events are assigned to one of two error classes:
–
Global Error
events that need to be resolved by maintenance personnel
–
Customer Self Service
(CSS) error events that may be resolved by
operating personnel
Global Error and CSS LEDs (see section
"Connectors and indicators" on
) indicate, if the defective component is a customer replaceable unit or
if maintenance personnel needs to be dispatched to replace the part.
I
The indicators also light up in standby mode and after a server restart
due to a power failure.
4.1.2.1
Global Error indicator
Ê
Check the Global Error indicator on the front or I/O panel of the server:
Ê
For further diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL), see section
– Software/agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I
For more information, see the "ServerView System Monitor" user
guide.
4.1.2.2
Customer Self Service (CSS) indicator
Ê
Check the CSS indicator on the front panel or I/O panel of the server.
Summary of Contents for PRIMERGY RX2520 M4
Page 6: ...6 Upgrade and Maintenance Manual RX2520 M4 ...
Page 22: ...Upgrade and Maintenance Manual RX2520 M4 Content ...
Page 98: ...98 Upgrade and Maintenance Manual RX2520 M4 Basic software procedures ...
Page 118: ...118 Upgrade and Maintenance Manual RX2520 M4 Power supply unit PSU ...
Page 194: ...194 Upgrade and Maintenance Manual RX2520 M4 Fans ...
Page 232: ...232 Upgrade and Maintenance Manual RX2520 M4 Expansion cards and backup units ...
Page 310: ...310 Upgrade and Maintenance Manual RX2520 M4 Accessible drives ...
Page 338: ...338 Upgrade and Maintenance Manual RX2520 M4 Front panel ...
Page 410: ...410 Upgrade and Maintenance Manual RX2520 M4 Appendix A ...
Page 412: ...412 Upgrade and Maintenance Manual RX2520 M4 Appendix B ...
Page 451: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...