92
Upgrade and Maintenance Manual
RX1330
M1
Power supply
6.1
Basic information
The server can be equipped:
– with a standard power supply unit (permanently built-in)
The power supply unit adjusts automatically to any mains voltage in the
range of 100 V - 240 V.
– or up to two hot-plug power supply units (slide-in units)
In its basic configuration, the server has one power supply unit that adjusts
automatically to any mains voltage in the range of 100 V - 240 V. Besides
the power supply unit, a second power supply unit can be installed optionally
to serve as a redundant power supply. If one power supply unit fails, the
second power supply unit in the redundant configuration ensures operation
can continue uninterrupted and the defective power supply unit can be
replaced during operation (hot-plug).
V
CAUTION!
The server supports a mains voltage in the range of 100 V - 240 V. You
may only operate the server if its rated voltage range corresponds to the
local mains voltage.