RX1330 M1
Upgrade and Maintenance Manual
269
System board and components
14.4.3 Replacing the TPM
V
CAUTION!
Advise your contact persons that they must provide you with TPM
backup copies. For security reasons, the TPM must be restored/re-
saved by the customer. After installing a new system board, the TPM
must be enabled. You may not clear the TPM data.
If the contact persons
DO NOT
have a backup copy available, inform
them that replacing the TPM board will cause to lose all data.
14.4.3.1 Preliminary steps
Ê
"Locating the defective server" on page 43
Ê
"Suspending BitLocker functionality" on page 63
Ê
"Shutting down the server" on page 45
Ê
"Disconnecting the server from the mains" on page 46
Ê
"Getting access to the component" on page 47
Ê
"Removing the defective system board" on page 279
Field Replaceable Unit
(FRU)
Hardware: 30 minutes
Tools:
Removing the system board:
– Phillips PH2 / (+) No. 2 screw driver
Replacing the TPM:
– Bit screw driver
– TPM bit insert
(
*
)
– thin slotted screw driver (2 x 0.4 mm)
(
*
)
(
*
)
For the Japanese market:
– Dedicated TPM screw driver (CWZ8291A)
– TPM module fixing tool (S26361-F3552-L909)
Summary of Contents for PRIMERGY RX1330 M1
Page 62: ...62 Upgrade and Maintenance Manual RX1330 M1 Basic hardware procedures ...
Page 150: ...150 Upgrade and Maintenance Manual RX1330 M1 Hard disk drives solid state drives ...
Page 156: ...156 Upgrade and Maintenance Manual RX1330 M1 Fans ...
Page 204: ...204 Upgrade and Maintenance Manual RX1330 M1 Expansion cards and backup units ...
Page 234: ...234 Upgrade and Maintenance Manual RX1330 M1 Optical disk drive ...
Page 312: ...312 Upgrade and Maintenance Manual RX1330 M1 Appendix ...