Basic hardware procedures
Standard power supply
Ê
If applicable, connect the mains plug to a grounded mains outlet in the in-
house power supply network.
Ê
Connect the power cord to the power supply unit.
Figure 10: Example: Locking the cable tie of a standard power supply unit
Ê
Thread the cable tie through the eye (1).
Ê
Pull the cable tie tight to secure the power cord (2).
The insulated connector cannot now be disconnected from the server
accidentally.
Redundant power supply
Ê
If applicable, connect the mains plugs to power outlets of the rack socket
strip.
I
To provide true phase redundancy, the second power supply unit
should be connected to a different AC power source from the other
power supply unit. If one AC power source should fail, the server will
still continue to run.
Ê
Connect the power cords to the power supply units.
Ê
Ensure that the status indicator on the power supply unit is lit green (see
section
"Indicators on hot-plug power supply units (slide-in units)" on
page 305
).
햳
햲
Summary of Contents for PRIMERGY RX1330 M1
Page 62: ...62 Upgrade and Maintenance Manual RX1330 M1 Basic hardware procedures ...
Page 150: ...150 Upgrade and Maintenance Manual RX1330 M1 Hard disk drives solid state drives ...
Page 156: ...156 Upgrade and Maintenance Manual RX1330 M1 Fans ...
Page 204: ...204 Upgrade and Maintenance Manual RX1330 M1 Expansion cards and backup units ...
Page 234: ...234 Upgrade and Maintenance Manual RX1330 M1 Optical disk drive ...
Page 312: ...312 Upgrade and Maintenance Manual RX1330 M1 Appendix ...