![Fujitsu PRIMERGY RX1330 M1 Upgrade And Maintenance Manual Download Page 144](http://html.mh-extra.com/html/fujitsu/primergy-rx1330-m1/primergy-rx1330-m1_upgrade-and-maintenance-manual_121084144.webp)
144
Upgrade and Maintenance Manual
RX1330
M1
Hard disk drives / solid state drives
7.3.3
Removing 3.5-inch HDD modules
7.3.3.1
Preliminary steps
Ê
If the HDD module to be removed is combined into a RAID array, please
proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V
CAUTION!
All data on all HDDs in the array will be lost! Be sure to back up your
data before deleting a RAID array.
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0 array if
defective.
V
CAUTION!
Removing an operational HDD module will result
in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section
"Performing a RAID array
rebuild" on page 85
.
Summary of Contents for PRIMERGY RX1330 M1
Page 62: ...62 Upgrade and Maintenance Manual RX1330 M1 Basic hardware procedures ...
Page 150: ...150 Upgrade and Maintenance Manual RX1330 M1 Hard disk drives solid state drives ...
Page 156: ...156 Upgrade and Maintenance Manual RX1330 M1 Fans ...
Page 204: ...204 Upgrade and Maintenance Manual RX1330 M1 Expansion cards and backup units ...
Page 234: ...234 Upgrade and Maintenance Manual RX1330 M1 Optical disk drive ...
Page 312: ...312 Upgrade and Maintenance Manual RX1330 M1 Appendix ...