Hard disk drives / solid state drives
7.3
3.5-inch HDD configurations
7.3.1
Equipping the 3.5-inch HDD bays
– If only one HDD module is installed, the HDD module will be installed in the
left bay (seen from the front) and dummy modules must be installed in the
free bays.
– Installing different capacities, install the biggest capacity first.
– Installing different rotating speed, install the fastest rotating speed first.
Mounting order
Figure 76: Mounting order with up to four 3.5-inch HDDs
HDD naming scheme
Figure 77: Naming scheme with up to four 3.5-inch HDDs
I
The HDD numbering as listed in the ServerView RAID Manager differs
from the HDD mounting order:
Position
Logical drive number ServerView RAID Manager display name
[1]
0
HDD vendor name (0)
[2]
1
HDD vendor name (1)
[3]
2
HDD vendor name (2)
[4]
3
HDD vendor name (3)