124
Upgrade and Maintenance Manual
RX1330
M1
Hard disk drives / solid state drives
7.2.6.3
Installing a 2.5-inch HDD/SSD dummy module
V
CAUTION!
If the removed HDD/SSD module is not replaced immediately, always
replace a dummy module into the unused HDD/SSD bay to comply with
applicable EMC regulations and satisfy cooling requirements.
Figure 58: Installing a 2.5-inch dummy module
Ê
Push the dummy module into the empty bay until it engages.
7.2.6.4
Concluding steps
No steps needed.
7.2.7
Replacing a 2.5-inch HDD/SSD module
V
CAUTION!
●
Only remove an HDD/SSD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD/SSD modules, see section
"Indicators on the
hot-plug HDD module" on page 309
.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less
Summary of Contents for PRIMERGY RX1330 M1