RX100 S4
Operating manual
37
Hardware installation
Installing/removing the server in/from the rack
3rd party rack
Certain general conditions must be met:
– Installation dimensions (see the dimensions shown in figure
2 on page 38
):
– You must ensure that the safety mechanisms on the server, e.g. stoppers or
retaining systems, are functioning correctly.
– The shape of the rack support uprights must ensure that the rails can be
bolted to the front.
– Telescopic rails screwed to the front
The rails have a linear alignment feature to ensure that they can be adjusted
to different rack depths.
– Climatic conditions.
To ventilate the server, an unimpeded air inlet on the front of the rack and an
air outlet on the rear of the rack are required.
In principle the ventilation concept is based on the necessary cooling being
provided by the horizontal self-ventilation of the installed devices (air flow
from front to back).
1
Front of rack
2
Rear of rack
A
Rack depth (comparison PRIMECENTER Rack 940/1000 mm)
B
Rack width (comparison PRIMECENTER Rack 700 mm)
C
Clearance for 19” installation level
C1
Front 19” installation level
C2
Rear 19” installation level
D
Cable routing area (cable area depth) and ventilation
E
Space for front panel and ventilation
F
Space for right and left support systems
P
PRIMERGY rack installation depth
a1
Front left support upright
a2
Front right support upright
b1
Rear left support upright
b2
Rear right support upright