RX100 S4
Operating manual
15
Introduction
Technical data
1.4
Technical data
Electrical data
Compliance with regulations and standards
Rated voltage range
100 V - 127 V or 200 V - 240 V
Frequency
50 Hz - 60 Hz
Rated current with basic configuration
100 V - 240 V / 1.94 A - 0.96 A
Max. rated current
100 V - 240 V / 4 A - 2 A
Effective power
234 W
Apparent power
249 VA
Heat dissipation
842 kJ/h (798 btu/h)
Main power fuse
16 A (6.3 A)
Protection class
I
Product safety and ergonomics IEC 60950 / EN 60950, UL/CSA 60950,
CAN/CSA 22.2 No. 60950 3rd. Ed.
Electromagnetic Compatibility
(standard power supply)
FCC class A
VCCI class A
AS/NZS CISPR 22 class A
CNS 13438 class A
Interference emissions
EN 55022
Harmonic current
EN 6100-3-2 JEIDA
Flicker
EN 61000-3-3
Interference immunity
EN 55024
CE marking to EU directives
Low Voltage Directive 73/23/EEC
Electromagnetic Compatibility 89/336/EEC