CX400 M4
Operating Manual
27
Product description
3.3.1.3
Indicators on the hot-plug HDD/SSD module
Figure 8: Indicators on the 2.5 inch HDD modules
Pos. Label
Indicator
Status
Description
1
Access
indicator
off
The HDD/SSD is inactive.
green on The HDD/SSD being accessed
2
Error
indicator
off
No HDD/SSD error detected.
orange
on
An HDD/SSD error has been
detected.
Possible causes:
– The drive is defective and
needs replacing.
– A RAID rebuild process has
failed.
– The HDD/SSD module has not
been inserted correctly.
flashing
orange
slowly
HDD/SSD RAID rebuild is in
progress. Data is being restored
after replacing a drive that has
been combined into a RAID array.
!