Fujitsu primequest 2400E2 Design Manual Download Page 54

PRIMEQUEST 2000 Series Design Guide 

2.6 PCI Box (4/4) 

A Configuration for Redundancy of PCI Boxes and PCI Box LH modules 

The effects of a failed PCI Box are taken into account. 

 

 
 
 

 

A Configuration for Failure Isolation of PCI Boxes 

SB 

IOU 

Partition#0 

SB 

Partition#1 

PRIMEQUEST 

IOU 

Advantage 

Even if one PCI Box fails, the failed 

PCI Box can be disconnected by a 

reboot and the system can be 

started using the other PCI Box. 

Disadvantage 

Both partitions stop when a PCI Box 

fails. 

PCI Box LH #0 

PCI Box #0 

PCI Box LH #1 

PCI Box LH #0 

PCI Box #1 

SB 

IOU 

Partition#0 

SB 

Partition#1 

PRIMEQUEST 

IOU 

PCI Box #0 

PCI Box #1 

Stop 

Redundancy of the PCI Boxes and PCI Box LH 
modules 

The PCI Box is  
disconnected 
 by a reboot. 

Not 

affected 

The PCI Box cannot be used  

until it is repaired. 

The failure in partition#1 is isolated from partition#0. 

PCI Box LH #1 

PCI Box LH #0 

PCI Box LH #1 

PCI Box LH #0 

For details on redundancy of PCI Express cards and connection destinations, refer to "

3.3.5 Network Configuration

". 

Failure 

Failure 

Stop 

Start in a  

degraded state 

Start in a  

degraded state 

Stop 

Advantage 

This configuration provides failure 

isolation. Even if the PCI Box for a 

partition fails, the other partition is 

not affected. 

Disadvantage 

The PCI Box for the relevant partition 

cannot be used until the PCI Box is 

repaired. 

Copyright 2016-2017 FUJITSU LIMITED 

PCI Box LH #1 

53 

Summary of Contents for primequest 2400E2

Page 1: ...FUJITSU Server PRIMEQUEST 2000 Series Design Guide CA92344 0696 07 ...

Page 2: ...ries Design Guide Table of Contents Preface 1 PRIMEQUEST Overview 2 Basic Hardware Configuration 3 Hardware Configuration Design 4 Operation Management Design 5 OS Support Appendices Copyright 2016 2017 FUJITSU LIMITED 1 ...

Page 3: ...e PRIMEQUEST 2000 series main unit For details on the operating environment of the software refer to the website of each software For details on virtualization refer to the document of each virtualization software Organization of Manuals The following figure shows the organization of manuals for the PRIMEQUEST 2000 series Copyright 2016 2017 FUJITSU LIMITED Operation Installation Design Linux RHEL...

Page 4: ... 2800B3 PRIMEQUEST 2800E2 PRIMEQUEST 2800E3 Microsoft Windows Server 2012 R2 Standard Windows Server 2012 R2 Windows Microsoft Windows Server 2012 R2 Datacenter Microsoft Windows Server 2012 Standard Windows Server 2012 Microsoft Windows Server 2012 Datacenter Red Hat Enterprise Linux 6 for Intel64 RHEL 6 for Intel64 RHEL 6 RHEL Linux Red Hat Enterprise Linux 7 for Intel64 RHEL 7 for Intel64 RHEL ...

Page 5: ... Microsoft product names are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Linux is the registered trademark of Linus Torvalds in the U S and other countries Red Hat and Red Hat Enterprise Linux are trademarks of Red Hat Inc registered in the U S and other countries Intel and Xeon are trademarks of Intel Corporation in the United St...

Page 6: ...PRIMEQUEST 2000 Series Design Guide Copyright 2016 2017 FUJITSU LIMITED 1 PRIMEQUEST Overview This chapter describes the overview of PRIMEQUEST For details refer to General Description 5 ...

Page 7: ...test Intel architecture Up to 1 partition 2800B2 Up to 8 CPUs and 144 cores 2800B3 Up to 8 CPUs and 192 cores Up to 16 PCIe slots Up to 4 partitions 2800E2 Up to 8 CPUs and 144 cores 2800E3 Up to 8 CPUs and 192 cores Up to 56 PCIe slots Up to 2 partitions 2400E2 Up to 4 CPUs and 72 cores 2400E3 Up to 4 CPUs and 96 cores Up to 56 PCIe slots For Enterprise For Business PRIMEQUEST 2800B2 PRIMEQUEST 2...

Page 8: ...oning including Extended Socket Not supported Supported RHEL Memory Scale up Board Not supported Supported RHEL Not supported Dynamic Reconfiguration Not supported Supported RHEL RAID Hardware RAID Software RAID Redundancy Memory IOU PSU FAN HDD SAS SSD PCI Express card MMB and power input system Hot plug IOU in a redundant configuration PSU in a redundant configuration FAN HDD in a RAID configura...

Page 9: ...xtended Socket Not supported Supported RHEL Memory Scale up Board Not supported Supported RHEL Not supported Dynamic Reconfiguration Not supported Supported RHEL SLES 12 SP1 RAID Hardware RAID Software RAID Redundancy Memory IOU PSU FAN HDD SAS SSD PCI Express card MMB and power input system Hot plug IOU in a redundant configuration PSU in a redundant configuration FAN HDD in a RAID configuration ...

Page 10: ...000 Series Design Guide 1 3 Supported OS Copyright 2016 2017 FUJITSU LIMITED For the latest information on the supported OSs refer to the following URL http sp ts fujitsu com dmsp Publications public osrel py pdf 9 ...

Page 11: ... Copyright 2016 2017 FUJITSU LIMITED Front Rear IO unit IOU System board SB Memory Scale up Board 1 Disk unit DU Management board MMB Power supply unit PSU FAN View without the front panel 1 Memory Scale up Boards are only available for the 2400E2 2400E3 10 ...

Page 12: ...nnection Configuration for the 2400E2 2400E3 1 5 2 Basic Configuration 2400E2 2400E3 Layout and Internal Connection Configuration for the 2400E2 2400E3 with Memory Scale up Board 1 5 3 Basic Configuration 2400E2 2400E3 with Memory Scale up Board Layout and Internal Connection Configuration for the 2800E2 2800E3 1 5 4 Basic Configuration 2800E2 2800E3 Copyright 2016 2017 FUJITSU LIMITED 11 ...

Page 13: ... 1 2 Copyright 2016 2017 FUJITSU LIMITED 2800B2 2800B3 Layout Component Max installable number Installed as standard SB 4 No must be ordered IOU 4 No must be ordered MMB 1 1 PSU 6 No must be ordered FAN 3 No DU 2 No AC cable 6 No must be ordered Basic components Front Rear 12 ...

Page 14: ...6 2017 FUJITSU LIMITED For details on the configuration refer to General Description Component Maximum number of ports and cards IOU onboard LAN ports 8 ports PCI Express slots on IOUs 16 cards 1 Maximum number of ports and cards for network connection 1 Three cards per 10GbE IO unit and four cards per 1GbE IO unit QPI QuickPath Interconnect 13 ...

Page 15: ... 1 2 Copyright 2016 2017 FUJITSU LIMITED 2400E2 2400E3 Layout Component Max installable number Installed as standard SB 2 No must be ordered IOU 4 No must be ordered MMB 2 1 PSU 6 No must be ordered FAN 4 No DU 2 No AC cable 6 No must be ordered Basic components Front Rear 14 ...

Page 16: ...uration refer to General Description Component Maximum number of ports and cards IOU onboard LAN ports 8 ports PCI Express slots on IOUs 16 cards 1 PCI Express slots on PCI Boxes 48 cards Maximum number of ports and cards for network connection 1 Three cards per 10GbE IO unit and four cards per 1GbE IO unit The number of available PCI Box slots depends on which type of IO unit is selected 15 ...

Page 17: ...ITSU LIMITED 2400E2 2400E3 with Memory Scale up Board Layout Component Max installable number Installed as standard SB 2 4 No SBs must be ordered Memory Scale up Board 3 IOU 4 No must be ordered MMB 2 1 PSU 6 No must be ordered FAN 3 No DU 2 No AC cable 6 No must be ordered Basic components Front Rear MSB Memory Scale up Board 16 ...

Page 18: ...ls on the configuration refer to General Description Component Maximum number of ports and cards IOU onboard LAN ports 8 ports PCI Express slots on IOUs 16 cards 1 PCI Express slots on PCI Boxes 48 cards Maximum number of ports and cards for network connection 1 Three cards per 10GbE IO unit and four cards per 1GbE IO unit The number of available PCI Box slots depends on which type of IO unit is s...

Page 19: ... 1 2 Copyright 2016 2017 FUJITSU LIMITED 2800E2 2800E3 Layout Component Max installable number Installed as standard SB 4 No must be ordered IOU 4 No must be ordered MMB 2 1 PSU 6 No must be ordered FAN 3 No DU 2 No AC cable 6 No must be ordered Basic components Front Rear 18 ...

Page 20: ...uration refer to General Description Component Maximum number of ports and cards IOU onboard LAN ports 8 ports PCI Express slots on IOUs 16 cards 1 PCI Express slots on PCI Boxes 48 cards Maximum number of ports and cards for network connection 1 Three cards per 10GbE IO unit and four cards per 1GbE IO unit The number of available PCI Box slots depends on which type of IO unit is selected 19 ...

Page 21: ...refer to 3 2 Key Points for Hardware Partitioning Design Multiple configurations can be operated in a single cabinet and multiple servers that are operated separately from each other can be integrated in the cabinet If a failure occurs in a partition the hardware can protect other partitions from being affected by the failure Copyright 2016 2017 FUJITSU LIMITED PCI Express card Partition A Partiti...

Page 22: ...pro actively monitoring the memory to detect a problem at the earliest possible time Data is copied if a problem is detected Memory Scale up Board Memory Scale up Boards are used for expanding the memory capacity of the partitions Memory Scale up Boards are only supported for the 2400E2 2400E3 A maximum of three boards can be installed in a cabinet A maximum of 3TB can be installed in a single boa...

Page 23: ...Active Processor Cores This function specifies the number of CPU cores to run in a partition The Active Processor Cores function is used in cases such as software license errors that occur when the number of CPU cores in SBs increases after the SBs are switched by the Reserved SB function Consult your software vendors before using this function to reduce the number of software licenses Extended Pa...

Page 24: ...ssible Notes on hot removal of SBs 2400E2 2800E2 supports hot removal of SBs for RHEL 7 1 or later 2400E3 2800E3 supports hot removal of SBs for RHEL 7 2 or later RAID For details refer to 3 3 Key Points for I O Configuration Design Software RAID and hardware RAID ensures the reliability and availability of the system Redundancy By duplicating or multiplexing internal components even if memory or ...

Page 25: ... This function collects system information when a problem occurs in the OS Cluster System For details refer to 3 4 Key Points for Cluster Configurations Partition redundancy that is based on an inter cabinet cluster or an intra cabinet cluster is supported Boot Devices The following boot types are supported Internal HDD SAS SSD RAID card HDD SAS SSD installed in a JX40 S2 RAID card iSCSI SAN boot ...

Page 26: ...s on IOUs are supported LAN cards are scheduled to be supported in the future Console Functions Video Redirection Connection This function remotely performs KVM operations from a console that is connected to a LAN This allows a virtual media function in which FD CD DVD drives on the console PC can be used as the drives for the PRIMEQUEST Text Console Redirection for Maintenance This function direc...

Page 27: ...t devices LV DIMM and SAS SSD are available A highly efficient power supply unit 80 PLUS platinum certified is available Optimized Cooling Cooling is optimized by finely controlling the FAN speed for each cooling group Reduction of Power Consumption Power capping for PRIMEQUEST can automatically lower system performance so as to keep power consumption under pre determined value Compliant with RoHS...

Page 28: ...QUEST 2000 Series Design Guide Copyright 2016 2017 FUJITSU LIMITED 2 Basic Hardware Configuration This chapter describes the basic configuration of each component For details refer to General Description 27 ...

Page 29: ...Driver installed to control the system LEDs that display the system status Intake Air Temperature Sensor A sensor that is installed for monitoring the intake air temperatures of the main unit System FRU A system FRU I2C EEPROM that is installed for storing information about the main unit Copyright 2016 2017 FUJITSU LIMITED System LEDs 28 ...

Page 30: ...lid state drives SAS SSDs can be installed on an SB In RAID configurations hot replacements can be performed for internal HDDs and SAS SSDs excluding RAID0 and non mirror configurations RAID0 RAID1 RAID1E RAID5 RAID6 and RAID10 are supported A hot spare disk is supported External Ports For a partition the following ports are supported for the local KVM The local KVM cannot be connected permanently...

Page 31: ...Hz 45 0MB 18 Yes Yes Yes Intel Xeon Processor E7 8867v3 2 50GHz 45 0MB 16 Yes Yes Yes Intel Xeon Processor E7 8860v3 2 20GHz 40 0MB 16 Yes Yes Yes Intel Xeon Processor E7 8891v3 2 80GHz 45 0MB 10 Yes Yes Yes Intel Xeon Processor E7 8893v3 3 20GHz 45 0MB 4 Yes Yes Yes Yes Installable Not installable Note For the latest information on the supported CPUs contact your sales representative The CPUs tha...

Page 32: ...Xeon Processor E7 8855v4 is installed in the system board Copyright 2016 2017 FUJITSU LIMITED Product number Performance Number of cores 2800B3 2400E3 2800E3 Intel Xeon Processor E7 8894v4 2 40GHz 60 0MB 24 Yes Yes Yes Intel Xeon Processor E7 8890v4 2 20GHz 60 0MB 24 Yes Yes Yes Intel Xeon Processor E7 8880v4 2 20GHz 55 0MB 22 Yes Yes Yes Intel Xeon Processor E7 8870v4 2 10GHz 50 0MB 20 Yes Yes Ye...

Page 33: ...Component Mounting Conditions in Administration Manual CPUs must be installed from CPU 0 on an SB in the order of the slot numbers SBs in which no CPU is installed cannot be incorporated in a PPAR block At least one set of memory modules two modules must be installed for a CPU Conditions for Installing Different CPUs Different types of CPUs can be installed in different PPAR blocks The CPUs must b...

Page 34: ...Different CPUs cannot be installed in the same PPAR block Different CPUs can be installed in different PPAR blocks Different types of CPUs can be installed in different PPAR blocks of a cabinet Partition 0 Partition 0 Partition 1 The CPUs must be supported in the PRIMEQUEST model Copyright 2016 2017 FUJITSU LIMITED CPU A CPU A CPU B CPU A CPU A CPU B CPU B CPU B 33 ...

Page 35: ...0 Flexible I O Partition 0 SB 0 IOU 0 Partition 0 Partition 1 IOU 1 Flexible I O SB 0 SB 1 This installation is not allowed because PPAR 0 is switched from SB 0 to SB 2 if a failure occurs in SB 0 Copyright 2016 2017 FUJITSU LIMITED CPU B CPU B CPU A CPU A IOU 0 Flexible I O Partition 0 Reserved SB SB 0 CPU A CPU A SB 1 SB 2 CPU A CPU A CPU B CPU B IOU 0 Flexible I O SB 0 CPU A CPU A SB 1 SB 2 CPU...

Page 36: ...CI Address mode For one CPU six sets of memory modules can be installed in the memory slots on the SB and another six sets of memory modules can be installed on an optional extended memory board Installed memory operates only when the relevant CPU is operating Installation Group Install memory modules in pairs where the memory slot numbers third digit has a difference of 3 128GB DIMMs are supporte...

Page 37: ...nly the same memory modules can be installed to the same memory channel of each Memory Buffer Different memory modules can be installed for different memory channels When the Memory Mirror function is used install the same configuration of memory in size and the number of modules in multiple memory channels that are used for mirroring When the Memory Spare function is used install the same memory ...

Page 38: ...re multiple patterns in installation order depending on whether the Memory Mirror function or Memory Spare function is used or not For details on installation order refer to G 2 1 DIMM mounting order and DIMM mixed mounting condition in Administration Manual and the following slides Example of Installation Order 1 CPU and Normal Mode The Same Type of Memory is Shown in the Same Color CPU MB Memory...

Page 39: ...artition is configured with a total of four boards that consist of system boards and Memory Scale up boards When one PPAR block is configured with eight CPUs Segment Mode CPU 0 CPU 1 Slot No 0A0 0A3 0B0 0B3 0C0 0C3 0D0 0C3 1A0 1A3 1B0 1B3 1C0 1C3 1D0 1D3 0A1 0A4 0B1 0B4 0C1 0C4 0D1 0C4 1A1 1A4 1B1 1B4 1C1 1C4 1D1 1D4 0A2 0A5 0B2 0B5 0C2 0C5 0D2 0C5 1A2 1A5 1B2 1B5 1C2 1C5 1D2 1D5 Normal Mode 1 1 4...

Page 40: ... one PPAR block is configured with eight CPUs two CPUs are installed in an SB When only one CPU is installed and Dynamic Reconfiguration is enabled IOU Dynamic Reconfiguration requires memory installation for CPU 0 in the above order DIMMs are available in sets of two CPU 0 CPU 1 Slot No 0A0 0A3 0B0 0B3 0C0 0C3 0D0 0C3 1A0 1A3 1B0 1B3 1C0 1C3 1D0 1D3 0A1 0A4 0B1 0B4 0C1 0C4 0D1 0C4 1A1 1A4 1B1 1B4...

Page 41: ...ination cannot be installed together in the same partition Different types of memory modules can be installed in a different partition on a different SB Partition 0 Partition 1 Partition 0 16GB 8GB DIMM x 2 64GB 32GB DIMM x 2 16GB 8GB DIMM x 2 32GB 16GB DIMM x 2 64GB 32GB DIMM x 2 Copyright 2016 2017 FUJITSU LIMITED 1 Memory rank A unit of data input and output by a memory controller from the DRAM...

Page 42: ...are and the DIMM rank in which the errors occurred is disconnected Memory Mirror and Memory Spare cannot be enabled at the same time Memory Spare Memory Mirror Mirroring is available only between the same types of memory Intra CPU mirroring DIMM pair Dual rank Spare DIMM pair DIMM pair Rank 0 Rank 0 DIMM pair Single rank Spare Rank 0 Rank 0 Rank 0 Rank 0 DIMM pair DIMM pair DIMM A DIMM B DIMM C DI...

Page 43: ...s cannot be installed For details refer to 2 2 2 Memory 2 7 Notes To use Memory Scale up Boards two CPUs must be installed in the system board of the connection destination However connections to Memory Scale up Boards are not available if the Intel Xeon Processor E7 8860v3 or the Intel Xeon Processor E7 8855v4 is installed in the system board SBs can be specified as Reserved SBs even if the parti...

Page 44: ...MMB provides a graphical user interface An MMB can be operated from a Web browser GUI on a remote PC and it is not necessary to prepare an operation management server separately Hardware management and monitoring function Consolidated management and monitoring of the power supply fan and hardware of each partition Hardware setup configuration change function Power control in the cabinet sensor mon...

Page 45: ...er and SNMP are managed collectively It is possible to add user definitions that allow operating only specific partitions This function prevents wrong operations and malicious operations on partitions MMB One board is included in the default configuration Another MMB can be added for redundancy SB Partition SB Partition Management and monitoring Copyright 2016 2017 FUJITSU LIMITED 44 ...

Page 46: ...nect to the management LAN for operation management of PRIMEQUEST Duplication is possible Port for maintenance x 1 Used by field engineers for maintenance COM port for an MMB console Used for initial setting User ports Port for maintenance COM port for an MMB console Copyright 2016 2017 FUJITSU LIMITED 45 ...

Page 47: ... external devices to an SB Up to four IOUs can be installed in a cabinet The number of PCI Express slots that can be installed in each IOU is as follows 1GbE IO unit 4 10GbE IO unit 3 To connect a PCI Box install a PCI Box connection card in the specified PCI Express slot on the IOU 1GbE IO units and 10GbE IO units can be installed together in the same cabinet Copyright 2016 2017 FUJITSU LIMITED 4...

Page 48: ...Up to four PCI cards with low profile bracket sizes can be installed 10GbE IO Unit A 10GbE IO unit has two 10GBASE T LAN ports Up to three PCI cards can be installed If the bracket size of the PCI card is full height up to two cards can be installed 1GbE IO Unit 10GbE IO Unit Copyright 2016 2017 FUJITSU LIMITED 47 ...

Page 49: ...nal storage device ETERNUS Example with LAN Cards Addition of LAN ports in a cluster configuration Example with a SAS Array Controller Card Connection to an external hard disk cabinet JX40 S2 Example with a SAS Card Connection to a backup cabinet PRIMERGY SX05 PRIMERGY SX05 ETERNUS JX40 S2 Copyright 2016 2017 FUJITSU LIMITED 48 ...

Page 50: ...AS SSDs excluding RAID0 and non mirror configurations RAID0 RAID1 RAID1E RAID5 RAID6 and RAID10 are supported A hot spare disk is supported Up to two RAID cards can be installed in a unit PCI Express Slot 0 RAID Card HDD 3 HDD 2 HDD 1 HDD 0 SAS SATA From IOU 0 IOU 2 For details on RAID configurations refer to 3 3 4 HDD Configuration Example with one RAID Card Example with two RAID Cards PCI Expres...

Page 51: ...A PCI Box can be divided into two partitions PCI Box LH modules each having six slots PCI Boxes power supply units and power cables for PCI Boxes need to be obtained separately PHP PCI Box LH PCI Box LH For details on the power supply configuration for a PCI Box refer to 3 5 1 Power Supply Redundancy IOU connection port Six PCI Express eight lanes slots Copyright 2016 2017 FUJITSU LIMITED PEXU PCI...

Page 52: ...of PCI Boxes Available number of slots 2400E2 2400E3 2800E2 2800E3 4 0 8 4 56 3 1 7 3 5 50 3 0 6 3 42 2 2 6 3 44 2 1 5 2 5 36 2 0 4 2 28 1 3 5 2 5 38 1 2 4 2 30 1 1 3 1 5 22 1 0 2 1 14 0 4 4 2 32 0 3 3 1 5 24 0 2 2 1 16 0 1 1 0 5 8 Note PCI Box connection cards PCNCs must be installed in IOUs to connect PCI Boxes One PCI Box connection cable is bundled with each PCNC Six of the PCI Box slots can b...

Page 53: ...Box PCI Boxes cannot be shared by servers Straight Connection Cross Connection Connection to Different PCI Boxes Connection from Different Cabinets to a PCI Box Connection from 1GbE IO Units and 10GbE IO Units Copyright 2016 2017 FUJITSU LIMITED The connection configuration depends on the type of IO unit that is to be installed 52 ...

Page 54: ...EQUEST IOU PCI Box 0 PCI Box 1 Stop Redundancy of the PCI Boxes and PCI Box LH modules The PCI Box is disconnected by a reboot Not affected The PCI Box cannot be used until it is repaired The failure in partition 1 is isolated from partition 0 PCI Box LH 1 PCI Box LH 0 PCI Box LH 1 PCI Box LH 0 For details on redundancy of PCI Express cards and connection destinations refer to 3 3 5 Network Config...

Page 55: ...whichever comes first Checking the status of the allowed write value etc The status can be checked with management software or with command line tools Estimate the amount of writes when designing the system In addition check the status regularly after system implementation If there is a possibility that the guaranteed predetermined write value is reached before the system reaches the end of its se...

Page 56: ...ncy power supply unit 200V 80 PLUS Platinum certified Power supply unit 200V Equivalent to an 80 PLUS Silver Power supply unit 100V Equivalent to an 80 PLUS Silver 2800B2 2800B3 2800E2 2800E3 does not support 100V Power Supply Configuration Input voltage Power feeding method Redundancy 2400E2 2400E3 2400E2 2400E3 with Memory Scale up Board 2800B2 2800B3 2800E2 2800E3 200V Single power feed Non red...

Page 57: ... PSU is installed A total of six units between the PSUs and the FANUs must be installed For details on the number of FANUs that must be installed and the installation slots refer to 4 5 1 PSU Configuration in General Description Copyright 2016 2017 FUJITSU LIMITED A total of six units between the PSUs and the FANUs are installed 56 ...

Page 58: ...ST 2000 Series Design Guide 2 10 Peripheral Configuration 1 4 Console Unit A PC is required to connect a console For details refer to 4 1 Key Points for Console Operation Copyright 2016 2017 FUJITSU LIMITED 57 ...

Page 59: ... a rack securing method 4 Arrange options Racks must be secured Rack securing method using an earthquake resistant kit Rack securing method using leveling feet None Earthquake resistant kit Rack without a stabilizer Racks do not need to be secured Rack with a stabilizer None Racks must be secured to the floor as a countermeasure for earthquakes measuring 80 gal or more Two sides for an additional ...

Page 60: ...center of gravity and stabilize the rack Attach a blank panel to the front of each unused space of the rack PRIMERGY and ETERNUS can also be installed PRIMERGY ETERNUS Rack External View For PRIMEQUEST it is recommended that one PRIMEQUEST unit is installed per rack In some cases two units can be installed x 1 unit recommended PRIMEQUEST Copyright 2016 2017 FUJITSU LIMITED 59 ...

Page 61: ...tance from the inside of the front door to the outside of the front rack posts 60mm or more C Distance from the outside of the front rack posts to the inside of the rear door 860mm or more For details on rack installation conditions refer to Hardware Installation Manual A B C Rear door Front door Front Posts Posts Copyright 2016 2017 FUJITSU LIMITED 60 ...

Page 62: ...PRIMEQUEST 2000 Series Design Guide Copyright 2016 2017 FUJITSU LIMITED 3 Hardware Configuration Design This chapter describes the key points for designing hardware configurations 61 ...

Page 63: ...MB IP address host name subnet mask and gateway address User accounts Name of the PRIMEQUEST system this is also used as the SNMP system name Management VLAN virtual IP addresses etc environment Copyright 2016 2017 FUJITSU LIMITED For details refer to 2 2 Key Points for the MMB Settings in Linux RHEL Installation Guide and 3 3 Connection and Setting of MMB in Installation Manual 62 ...

Page 64: ...s Memory Scale up Boards and CPUs per partition Functions That are Used for Partition Configuration For details refer to 3 2 2 Functions That are Used for Partition Configuration Home SB Reserved SB function Dynamic Reconfiguration function Switching Reserved SB Rules For details refer to 3 2 3 Switching Reserved SB Rules Configuration Example For details refer to 3 2 4 Configuration Example Guide...

Page 65: ... it is recommended to set them in a partition with the lowest partition number and also incorporate SBs with lower SB numbers in the partition It is recommended that the SB with the lowest SB number is specified as the Home SB When including DUs and PCI Boxes in a partition include the IOU for connecting these components in the same partition Note that the performance and the number of software li...

Page 66: ...The Total Numbers of System Boards Memory Scale up Boards and CPUs per Partition When multiple SBs are used to configure a partition For the 2800B2 2800B3 2800E2 2800E3 two CPUs must be installed in each SB For the 2400E2 2400E3 the same number of CPUs must be installed between the SBs When 128GB DIMMs are used a single partition can only be configured with one SB A single partition cannot be conf...

Page 67: ...ce The clock source of the Home SB becomes the clock source in the partition Selection of the Home SB Specify the Home SB by using the MMB Web UI If the Home SB is not specified directly the first SB that is incorporated in the partition is specified as the Home SB If the Home SB is removed from the partition or is degraded the SB with the lowest number in the partition is specified as the Home SB...

Page 68: ...that has only one SB even if the SB fails or it is degraded the partition can be recovered During operation of a partition an SB in the partition can be specified as a Reserved SB An SB that is used in a partition of a test environment during normal operation can be incorporated in a partition of the production environment as a Reserved SB if a failure occurs 2800B2 2800B3 is not supported R Reser...

Page 69: ...ed the Reserved SB is forced to be activated Saving the Partition Configuration Information Before Reserved SB switching is performed the partition configuration information for the entire cabinet is automatically saved to the MMB The latest partition configuration information overwrites the existing information right before a Reserved SB replaces the failed SB before the system reboots The saved ...

Page 70: ...eserved SB Partition 0 IOU 0 SB 0 CPU CPU SB 1 CPU CPU For a single partition multiple Reserved SBs can be set Partition 0 IOU 0 SB 0 CPU CPU SB 1 CPU CPU SB 2 CPU CPU Reserved SB SB 2 CPU CPU SB 3 CPU CPU Reserved SB Reserved SB OK OK IOU 1 Reserved SB An SB can be set as a Reserved SB for multiple partitions SB 2 CPU CPU Reserved SB OK Partition 1 Partition 0 IOU 0 SB 0 CPU CPU SB 1 CPU CPU IOU ...

Page 71: ... installation conditions as the partition can be set as a Reserved SB Partition 0 IOU 0 SB 0 CPU CPU SB 1 CPU CPU SB 2 CPU SB 3 CPU CPU Reserved SB Reserved SB OK NG Different types Partition 0 IOU 0 SB 0 8GB 8GB SB 1 8GB 8GB SB 2 SB 3 Reserved SB Reserved SB OK 32GB 32GB 16GB 16GB Reserved SB settings that make a configuration violate the CPU installation rules after an SB is replaced with a Rese...

Page 72: ...number of software licenses in advance If a volume license or package product is used in a Windows OS or if the SB being used is not an SB that was purchased together with the enable kit license authentication may be demanded after Reserved SB switching occurs Partition 0 IOU 0 SB 0 CPU CPU SB 1 CPU SB 2 CPU CPU Reserved SB Failure IOU 1 Partition 0 IOU 0 SB 0 CPU CPU SB 1 CPU SB 2 CPU CPU Failed ...

Page 73: ...ed SB Setting Rules 4 4 When using Reserved SBs use NTP for time synchronization that is performed after switching If devices are connected to the external VGA and USB ports on the Home SB and the Home SB is replaced those devices must be connected to the newly replaced Home SB Copyright 2016 2017 FUJITSU LIMITED 72 ...

Page 74: ... Supported Models 2400E2 2400E3 2800E2 2800E3 Supported OSs RHEL 6 6 or later and RHEL 7 1 or later Supported Functions Hot addition Hot addition of SBs and IOUs with PCI Box LH modules is possible with supported OSs and models Hot removal Hot removal of IOUs with PCI Box LH modules is possible with supported OSs and models Notes on hot removal of SBs 2400E2 2800E2 supports hot removal of SBs for ...

Page 75: ...SMI2 lane switchover 2 Detection of PCI Express lane speed degradation between a CPU and an IOU 2 1 Actual Reserved SB switching occurs when the partition is started after a condition for Reserved SB switching is met 2 Because the partition operation continues Reserved SB switching occurs when the partition is rebooted manually When the Home SB is Switched When the Home SB is switched to a Reserve...

Page 76: ...d to replace the failed SB in the partition with the lowest partition number R R Reserved SB H H H H H Home SB R Example An SB is Set as a Reserved SB for Two Partitions If SB 0 and SB 2 Fail Simultaneously Partition 1 Partition 0 Partition 1 Partition 0 The setting of SB 3 as the Reserved SB for partition 1 is automatically cancelled when Reserved SB switching occurs The SB with the lowest SB num...

Page 77: ...Reserved SBs Are Set for a Partition When there are Reserved SBs that do not belong to any partition the Reserved SB with the highest SB number is used first R H H Example Multiple SBs SB 2 and SB 3 are Set as Reserved SBs for Partition 0 If SB 1 Fails R Partition 1 Partition 0 Partition 1 Partition 0 R Reserved SB H Home SB R R R R H H Copyright 2016 2017 FUJITSU LIMITED 76 ...

Page 78: ...rtition for which a Reserved SB is used The Reserved SB with the highest SB number is used first SB 0 SB 1 SB 2 SB 3 IOU 0 IOU 1 IOU 2 IOU 3 SB 0 SB 1 SB 2 SB 3 IOU 0 IOU 1 IOU 2 IOU 3 3 2 3 Switching Reserved SB Rules 4 5 R R H H H H Example Two SBs are Set as Reserved SBs for Two Partitions If SB 0 and SB 1 Fail Simultaneously R R R Reserved SB H Home SB Partition 1 Partition 0 Partition 1 Parti...

Page 79: ...f Reserved SBs the Reserved SB with the highest SB number is used first If All Partitions Are Powered On The Reserved SB with the highest SB number is used first Then the partition with this Reserved SB is stopped Example When the Reserved SBs SB 1 SB 2 and SB 3 for Partition 0 Belong to Other Partitions If SB 0 Fails R H H H H R R H R H R R H R R R R Cannot be used Partition 0 Partition 1 Partiti...

Page 80: ...C servers and higher reliability Core system reconfiguration open MF UNIX server replacement and DB server ERP infrastructure Prerequisites This section assumes that the following items are predetermined The number of partitions The number of CPUs and the number of cores The lowest memory capacity Guidelines for Model Selection When I O scalability is highly important and the Dynamic Reconfigurati...

Page 81: ...e CPU core 1GB of memory and one I O PCI card G Copyright 2016 2017 FUJITSU LIMITED Purpose High availability High performance high functionality Server integration Configuration example A B C D E F G Inter cabinet cluster Intra cabinet cluster Reserved SB switching Multiple CPUs Many PCI Express cards Physical partitioning PPAR Extended partitioning Ext Par Target model Two cabinets of the same m...

Page 82: ... operation continues Example High reliability database for a large number of users that is installed in multiple cabinets SB CPU CPU Memory Memory IO unit PCI card PCI card IO unit PCI card PCI card SB CPU CPU Memory Memory IO unit PCI card PCI card IO unit PCI card PCI card SB CPU CPU Memory Memory IO unit PCI card PCI card IO unit PCI card PCI card SB CPU CPU Memory Memory IO unit PCI card PCI c...

Page 83: ...t Memory Mirror configuration Clustering between PPAR 0 and PPAR 1 If a failure occurs node switching occurs immediately and the system operation continues Cluster configuration for small sized installation installation of one PRIMEQUEST Example High reliability database for a user base that is small to medium sized vSphereHA SB CPU CPU Memory Memory IO unit PCI card PCI card IO unit PCI card PCI ...

Page 84: ...reduced No additional software is required because the availability is based on hardware Without additional hardware or special settings configurations and operations can be achieved just by setting the firmware Example Small to medium sized high availability system FT server replacement excluding nonstop systems SB 0 CPU CPU Memory Memory IO unit PCI card PCI card PCI card PCI card SB 1 CPU CPU M...

Page 85: ...ition and continues the operation If a failure other than a core failure occurs then the system disconnects the SB that contains the failed part restarts the partition with 6 CPU configuration and continues the operation Example In memory high performance database SAP HANA SB CPU CPU Memory Memory SB CPU CPU Memory Memory SB CPU CPU Memory Memory IO unit SB CPU CPU Memory Memory IO unit Partition ...

Page 86: ... Example Communication HUB server desktop virtualization server SB CPU CPU Memory Memory SB CPU CPU Memory Memory Partition 0 IO unit Connection card PCI card PCI card Connection card PCI Box PCI Box PCI Box PCI Box IO unit Connection card PCI card PCI card Connection card IO unit PCI card PCI card IO unit PCI card PCI card Connection card Connection card Connection card Connection card 4 PCI Boxe...

Page 87: ...at least one IOU After the initial build the configuration can be modified based on the operation condition When Dynamic Reconfiguration is not used the PPAR block to be modified must be stopped Example Server integration enhancement of the future scale up range of a server SB CPU CPU Memory Memory IO unit PCI card PCI card PCI card PCI card SB CPU CPU Memory Memory IO unit PCI card PCI card PCI c...

Page 88: ...ioning SB IO unit PCI card PCI card PCI card PCI card SB IO unit PCI card PCI card PCI card PCI card Physical Partition 0 Physical Partition 1 SB IO unit PCI card PCI card PCI card PCI card SB IO unit PCI card PCI card PCI card PCI card Ext Par 0 Ext Par 1 PRIMEQUEST 2800E3 Memory Memory Memory Memory Memory Memory Memory Memory Memory Memory Memory Memory Memory Memory Memory Memory Core Core Cor...

Page 89: ...s refer to 3 3 3 Obtaining RAID Cards and FBUs HDD Configuration For details refer to 3 3 4 HDD Configuration Guidelines for Selecting a RAID Configuration for HDDs Software RAID Hardware RAID SAN boot Memory Dump Function Network Configuration For details refer to 3 3 5 Network Configuration Network Types and Usage Network Redundancy I O Space Settings for PCI Devices For details refer to 3 3 6 S...

Page 90: ...y device Preboot eXecution Environment PXE LAN card and LAN port on an IOU Boot via remote operation Boot from a virtual media Device or file that is set as a virtual media Boot from a device or file that is set as a virtual media Boot from a device connected to the front USB port on the Home SB USB connected device e g CD and DVD Boot from a USB connected device that is used temporarily for opera...

Page 91: ...lated unavailable Intra cabinet cluster configuration The number of partitions that are used up to 2 must be stopped at the same time when maintenance is being performed No partitions need to be stopped at the same time because internal storage is not shared between the partitions Connection source Shared Not shared IOU 0 DU 0 RAID 0 HDD 2 3 DU 0 RAID 0 HDD 0 1 2 3 IOU 1 DU 0 RAID 1 HDD 0 1 DU 0 R...

Page 92: ...nal RAID Cards in DUs Obtain FBUs optional for each RAID card Obtain RAID software licenses optional RAID Cards in 1GbE IO Units for JX40 S2 Connection Obtain FBUs optional for each RAID card installed in Slot 1 and Slot 2 Obtain FBUs optional different from the FBUs for SBs DUs Obtain an FBU installation kit this kit uses Slot 0 exclusively FBUs cannot be connected to RAID cards that are installe...

Page 93: ...ls that are supported by the SAS array controller card that is connected to JX40 S2 Available at the RAID level of the storage device being used Device duplication at boot time Not supported Supported Supported Supported Supported Notes 1 2 If an unpredictable power supply problem occurs data in the cache that is equipped in a hardware RAID or disk may be lost To avoid such a problem make sure to ...

Page 94: ...rocessing takes a longer time and the conventional media access processing is delayed If there are restrictions in operation the following options are recommended Use ETERNUS Replace the HDD with a SAS SSD When using an internal SSD for a PCI slot note the following points The SSD cannot be used as a boot drive When a failed SSD is replaced the integrity of the data in the drive cannot be guarante...

Page 95: ...with the main server unit by default Hard disk redundancy on an external file unit A RAID configuration can be created in the file unit on an external storage device such as ETERNUS For details refer to the manual for the file unit RAID0 RAID1 RAID1E RAID5 RAID6 RAID10 RAID50 and RAID60 can be configured Hot swapping internal HDDs is supported excluding RAID0 and non mirror configurations RAID man...

Page 96: ...s Physical memory size 300MB Kernel memory dump Records the information only in the kernel memory space Depends on the memory space during system operation Minimum memory dump Records the minimum information that is useful for identifying the problem 128KB or 256KB Automatic memory dump Records information that is equivalent to the conventional kernel memory dump The following points are different...

Page 97: ...lternative area that is used if a device error occurs Installed memory capacity 512MB N areas Installed memory capacity 1GB 0 9 1st generation Required Error Error Acquisition Installed memory capacity 1GB 0 9 2nd generation Save data to a disk that is not managed with GDS RAW device Save data to a disk that is not managed with GDS When creating a dedicated disk partition such as var crash for sav...

Page 98: ...onfigurations Internal LAN The LAN for connecting each partition to MMBs for internal communication Maintenance LAN The LAN that is used for maintenance For connecting a maintenance terminal port for maintenance On the external switching hub device for connecting to the management LAN for MMBs select Disable for the spanning tree protocol function Management server Management LAN MMB 0 User port R...

Page 99: ...nfiguration 2 5 Redundancy of Internal Ports Concepts of Reliable Configurations When configuring partitions with multiple components install internal ports on different components Example of IOUs Separate IOUs from each other IOU 1 PCI Express Slots LAN IOU 0 Copyright 2016 2017 FUJITSU LIMITED 98 ...

Page 100: ... multiple ports cannot be used Because the card is duplicated the system can continue to operate safely 3 3 5 Network Configuration 3 5 Configuration That Focuses on Redundancy Multiple channel ports on a PCI Express card are used effectively Copyright 2016 2017 FUJITSU LIMITED PCI Box connection card PCI Box 1000Base T Dual FC card Single Empty 1000Base T Dual FC card Single Empty Not used Not us...

Page 101: ...undant configuration of the user ports on the MMBs that are connected to the management LAN with tools such as the bonding driver PRIMECLUSTER GLS and Intel PROSet When MMBs are duplicated but user ports are not the active MMB must be switched manually if an MMB fails For details refer to 1 3 3 Redundant configuration of the management LAN in Administration Manual 3 3 5 Network Configuration 4 5 C...

Page 102: ... PCI Box connection card Can be duplicated Can be duplicated IOU IB card Can be duplicated Replacement of an Ethernet Environment with InfiniBand Cards InfiniBand cards with a wide bandwidth of 40Gbps or 56Gbps can accommodate more networks than when a 10GbE environment is used InfiniBand cards can be used for the paths to synchronize databases Use of InfiniBand cards with PCIe SSDs can provide be...

Page 103: ...he size of the I O space is 64KB for all models A 4KB area of the I O space can be assigned per device The assignment is possible for up to 15 devices that is 16 devices in total including one device that is reserved for a PCH The following devices can be assigned Onboard LANs RAID cards in SBs RAID cards in DUs PCI Express slots on IOUs PCI Boxes Copyright 2016 2017 FUJITSU LIMITED 102 ...

Page 104: ... of the I O space Reserve an I O resource for each device including onboard devices such as IOUs for I O resources and PCI Express cards that are included in a partition This type of assignment is useful for assigning I O space to specific devices and cards if there are more than 16 devices that require the I O space Auto assignment of the I O space This type of assignment is easy to use and can b...

Page 105: ... reliability in the middle layer and application layer Inter cabinet cluster for securing work continuity Intra cabinet cluster for improving work continuity Cluster software Windows Windows Server Failover Clustering WSFC RHEL PRIMECLUSTER Inter cabinet cluster Countermeasures against server failures Intra cabinet cluster Countermeasures against partition failures Flexible I O spare SB Countermea...

Page 106: ...munication is performed periodically to monitor for problems There are two types of cluster systems inter cabinet cluster and intra cabinet cluster For details refer to 3 4 1 Inter Cabinet Cluster and 3 4 2 Intra Cabinet Cluster Windows Clustering with Windows Server Failover Clustering OS standard function is recommended A server for Active Directory AD server is required separately RHEL Clusteri...

Page 107: ...n in the number of CPUs CPU frequency memory capacity HDD capacity and number of HDDs Intra Cabinet Cluster All nodes have the same configuration in the number of CPUs CPU frequency memory capacity HDD capacity and number of HDDs If an IOU fails the redundancy of the system is lost and components such as the midplane become single points of failure 3 4 Key Points for Cluster Configurations 3 4 Cop...

Page 108: ...er cabinet No No No Oracle Clusterware EE RAC Intra cabinet Yes Yes Yes Inter cabinet Yes Yes Yes Windows WSFC excluding RAC Intra cabinet No Yes Yes Inter cabinet Yes Yes Yes WSFC RAC Intra cabinet inter cabinet No No No Oracle Clusterware SE2 RAC Intra cabinet No No No Inter cabinet No No No Oracle Clusterware EE RAC Intra cabinet Yes Yes Yes Inter cabinet Yes Yes Yes Note When RAC is used PRIME...

Page 109: ...ter software BMC MMB 0 Active MMB 1 Standby Cabinet 0 Partition 0 Cluster software BMC MMB 0 Active MMB 1 Standby Cabinet 1 Cluster interconnect Operation LAN Management LAN Windows The private network is configured separately from the public network operation LAN Cabinet 1 Partition 0 Cluster service Cabinet 0 Partition 0 Cluster service AD server Private network Public network operation LAN Team...

Page 110: ...ility of the entire system including the software layer is ensured Windows Partition X Cluster service AD server Private network Public network Operation LAN Partition Y Cluster service Copyright 2016 2017 FUJITSU LIMITED Linux MMB 0 Active MMB 1 Standby Cluster interconnect Operation LAN Partition X Cluster software BMC Partition Y Cluster software BMC Management LAN SVmco SVmco e g PRIMECLUSTER ...

Page 111: ...feed and dual power feed UPS Redundancy For details refer to 3 5 2 UPS Redundancy Guidelines for Selecting a 200V Power Distribution Box For details refer to 3 5 3 Guidelines for Selecting a 200V Power Distribution Box AC200V Power Distribution Box Brief Specifications Guidelines on the Number of AC200V Power Distribution Boxes Copyright 2016 2017 FUJITSU LIMITED 110 ...

Page 112: ...ibution panel AC100V AC power supply 0 system PSU PSU PSU Failure With Redundant Power Supply 4 1 CB Customer s distribution panel AC100V AC power supply 0 system CB PSU PSU CB PSU CB When using a redundant configuration or dual power feed for the main unit also use the same power supply configuration for the PCI Boxes PSU CB PSU CB CB Power failure CB PSU Customer s distribution panel AC200V If a...

Page 113: ...ower Supply Unit PSU Copyright 2016 2017 FUJITSU LIMITED Dual Power Feed Redundant UPS System 1 1 UPS 0 PSU PSU PSU PSU Configuring a redundant UPS system prevents the system from going down PSU Failure PSU UPS 1 With Redundant Power Supply Redundant UPS System 2 1 PSU PSU PSU PSU PSU PSU UPS 0 UPS 1 UPS 2 Configuring a redundant UPS system prevents the system from going down Failure 112 ...

Page 114: ... 24A BOX 16A per box Model 200V non redundant configuration 200V redundant configuration 200V dual power feed configuration 2400E2 2400E3 1 1 2 2400E2 2400E3 with Memory Scale up Board 1 2 2 2800E2 2800E3 2 2 4 2800E2 2800E3 2800B2 2800B3 1 4 500VA or less 1 2 2 1 Calculate the required number of power distribution boxes according to the maximum apparent power The maximum apparent power can be cal...

Page 115: ... 2000 Series Design Guide Copyright 2016 2017 FUJITSU LIMITED 4 Operation Management Design This chapter describes the key points for designing operation management For details refer to Administration Manual 114 ...

Page 116: ...Video redirection Control and management of the OS in a partition using images Management LAN It is difficult to acquire operation logs or automate operations log acquisition can be performed by using an application with a log acquisition function A PC in which JRE is installed must be connected to the management LAN If the resolution on the server is 800 x 600 part of the screen may not be displa...

Page 117: ...or Console Operation 2 2 Console Connection Configuration SW redundancy Redundancy with teaming PRIMECLUSTER GLS etc Virtual media Video redirection Text console Management LAN Maintenance LAN Operation LAN IOU IOU Copyright 2016 2017 FUJITSU LIMITED 116 ...

Page 118: ...oducts software infrastructure software resource management serverview resource orchestrator A single screen for displaying server information in which different operations and monitoring between platforms are integrated Server operations start stop and reboot operations through the screen Automation with a CLI is also possible Functions for supporting the entire virtual environment operation Inte...

Page 119: ...er If a problem occurs on the primary management server monitoring can be continued by switching to the secondary management server Operations on the monitoring screen are restricted to prevent unintended operations and unauthorized access For details refer to Appendix J Systemwalker Centric Manager Linkage in Administration Manual Copyright 2016 2017 FUJITSU LIMITED Systemwalker Centric Manager C...

Page 120: ...tion Manual Backup Mechanism Configuration information is stored in the System FRU I2C EEPROM on the OPL This processing is performed regularly or when MMB firmware is updated The same information is stored also in the flash memory of the MMB When duplicated MMBs are used the same information is always stored in both MMBs Backup Contents Firmware setting information Device identification informati...

Page 121: ...nt for Windows Arcserve Backup for Windows Yes Arcserve Backup for Windows Disaster Recovery Option For details refer to Linux RHEL Design Guide Floppy disk drives cannot be connected to the PRIMEQUEST 2000 series Select a method that does not require direct connection of a floppy disk drive The software support information is as of June 2016 For the latest software information contact your sales ...

Page 122: ...works as an NTP client that is connected to external NTP servers to synchronize time Each partition Each partition works as an NTP client that is connected to external NTP servers To ensure the stability of the NTP operation specify multiple NTP servers from each NTP client Select NTP servers that have a high precision clock in the Internet or intranet NTP server Primary NTP server Secondary NTP s...

Page 123: ...PRIMEQUEST 2000 Series Design Guide Copyright 2016 2017 FUJITSU LIMITED 5 OS Support This chapter describes information on the OS 122 ...

Page 124: ...rrangement Information For details on the types of OSs and support contact your sales representative For details on OS specifications refer to Appendix B OS Specifications and the website of each vendor Copyright 2016 2017 FUJITSU LIMITED 123 ...

Page 125: ...PRIMEQUEST 2000 Series Design Guide Copyright 2016 2017 FUJITSU LIMITED Appendices 124 ...

Page 126: ...ows RHEL SLES Oracle Linux Oracle VM VMware DSNAP Yes Software Support Guide Yes ServerView Operations Manager Yes Yes Yes ServerView Agentless Service Yes Yes Yes Yes Yes ServerView Agent Yes Yes Yes Yes Yes ServerView RAID Manager Yes Yes Yes Yes Yes ServerView CIM Provider Yes SVmco Yes HBA blockage function Yes Dynamic Reconfiguration utility Yes Yes 1 Yes Supported Not supported Copyright 201...

Page 127: ...ers Windows Drivers are provided with ServerView Suite For the latest versions contact your sales representative Related Software Server Management Software For details refer to 1 5 3 Server management software in General Description Copyright 2016 2017 FUJITSU LIMITED 126 ...

Page 128: ...le size 16TB implementation restrictions the logical maximum value is 2 64 1 clusters ReFS which is the latest file system for Windows Server 2012 can be used for data areas but ReFS is not recommended because its use has not been proven well OS type R2 Datacenter R2 Standard Datacenter Standard CPU Maximum number of sockets 8 Maximum number of cores 192 Maximum number of logical CPUs 384 when Hyp...

Page 129: ...6 Emulex Fibre Channel lpfc driver 256 65 536 MegaRAID SAS megaraid_sas driver 8 8 PCI Maximum number of PCI slots All slots can be used PCI Hot Plug PCI Box is supported No IOU is supported Specification of the main unit MSI support OS driver Common between x86 and Intel64 Kernel MSI and MSI X are supported FusionMPT MSI is supported but MSI X is not supported INTx is used by default LPFC MSI and...

Page 130: ...hnical SLES 12 https www suse com releasenotes x86_64 SUSE SLES 12 TechInfo OS type SLES 11 SP4 SLES 12 SP1 CPU Maximum number of logical CPUs 4 096 8 192 Memory Maximum memory capacity 24TB Disk Maximum file system size 16TB ext3 1EB ext4 Maximum file size 2TB ext3 1EB ext4 PCI Maximum number of PCI slots All slots can be used PCI Hot Plug PCI Box is supported No IOU is supported Specification of...

Page 131: ...cd E52668_01 E67200 html section xv3 gvd kn html OS type Oracle Linux 7 Update 2 CPU Maximum number of logical CPUs 2 048 Memory Maximum memory capacity 64TB Disk Maximum LUN capacity 50TB Maximum file system size bfrts 50TB ext4 50TB XFS 500TB Maximum file size bfrts 50TB ext4 50TB XFS 16TB PCI Maximum number of PCI slots All slots can be used PCI Hot Plug Not supported Firmware UEFI support Supp...

Page 132: ...g URL http docs oracle com cd E64076_01 E64077 html vmrns limits html OS type Oracle VM 3 4 CPU Maximum number of logical CPUs 288 Number of vCPUs per virtual machine PVM 128 HVM 128 Memory Maximum memory capacity 6TB Disk in OCFS2 Maximum number of LUNs 1000 Maximum volume capacity 64TB PCI Virtual NICs PVM 31 HVM 8 Maximum number of physical NIC ports For details refer to Network Maximums in Cha...

Page 133: ...lus CPU Maximum number of logical CPUs 320 Number of vCPUs per virtual machine 64Way Memory Maximum memory capacity 4TB Disk in VMFS Maximum number of LUNs 256 Maximum volume capacity 64TB PCI Maximum number of FC HBAs 8 Maximum number of physical NIC ports For details refer to Networking Maximums in Configuration Maximums Firmware UEFI support vSphere 5 5 GA update1 Supported vSphere 5 5 update2 ...

Page 134: ...tandard Enterprise Enterprise Plus CPU Maximum number of logical CPUs 480 Number of vCPUs per virtual machine 128Way Memory Maximum memory capacity 6TB Disk in VMFS Maximum number of LUNs 256 Maximum volume capacity 64TB PCI Maximum number of FC HBAs 8 Maximum number of physical NIC ports For details refer to Networking Maximums in Configuration Maximums Firmware UEFI support Supported Note The nu...

Page 135: ...Standard Enterprise Enterprise Plus CPU Maximum number of logical CPUs 576 Number of vCPUs per virtual machine 128Way Memory Maximum memory capacity 12TB Disk in VMFS Maximum number of LUNs 512 Maximum volume capacity 64TB PCI Maximum number of FC HBAs 8 Maximum number of physical NIC ports For details refer to Networking Maximums in Configuration Maximums Firmware UEFI support Supported Note The ...

Page 136: ...such as reuse on your own website or uploading to another server Warranty Restrictions Fujitsu Limited does not guarantee the accuracy merchantability or applicability to your purpose of these contents and shall bear no liability for any damages that are incurred as a result of the use of these contents These contents are subject to change or removal without notice For more information on this pro...

Page 137: ...Copyright 2016 2017 FUJITSU LIMITED 136 ...

Reviews: