Interface
5-122 C141-E203-01EN
(42) READ MULTIPLE EXT (X’29’)
•
Description
This command is the extended command of the READ MULTIPLE command.
The LBA specification is increased from 28 bits to 48 bits, and the maximum
number of sectors that can be transferred by a single command is changed from
100h to 10000h. Other command controls are the same as those of the READ
MULTIPLE command.
•
Error reporting conditions
(1) The command was issued in CHS mode (ST = 51h, ER = 04h).
The other error reporting conditions are the same as those of the READ
MULTIPLE command.
At command issuance (Shadow Block Registers setting contents)
CM
0 0 1 0 1 0 0 1
DH
1 L 1 x
xx
CH EXP
CH
CL EXP
CL
SN EXP
SN
SC EXP
SC
FR EXP
FR
LBA (47-40)
LBA (23-16)
LBA (39-32)
LBA (15-8)
LBA (31-24)
LBA (7-0)
Sector count (15-8)
Sector count (7-0)
xx
xx
At command completion (Shadow Block Registers contents to be read)
ST Status
information
DH
1 L 1 x
xx
CH EXP
CH
CL EXP
CL
SN EXP
SN
SC EXP
SC
ER
LBA (47-40)
LBA (23-16)
LBA (39-32)
LBA (15-8)
LBA (31-24)
LBA (7-0)
xx
xx
Error information
Summary of Contents for MHT2040BH
Page 1: ...C141 E203 01EN MHT2080BH MHT2060BH MHT2040BH DISK DRIVES PRODUCT MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 42: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 74: ...This page is intentionally left blank ...
Page 246: ...This page is intentionally left blank ...
Page 250: ...This page is intentionally left blank ...
Page 260: ...This page is intentionally left blank ...
Page 262: ...This page is intentionally left blank ...
Page 263: ......
Page 264: ......