Interface
5-114 C141-E203-01EN
•
Error reporting conditions
(1) The command has been issued more than twice (ST = 51h, ER = 10h).
(2) The READ NATIVE MAX ADDRESS command has not been issued prior to
the SET MAX ADDRESS command. (ST = 51h, ER = 04h).
(3) The SET MAX ADDRESS (EXT) command has been issued
(ST = 51h, ER = 04h).
(4) A SATA communication error occurred (ST = 51h, ER = 14h).
At command issuance (Shadow Block Registers setting contents)
CM
1 1 1 1 1 0 0 1
DH x
L
x
x HD
No./LBA
CH
CL
SN
CYL No. [MSB] / LBA
CYL No. [LSB] / LBA
SCT No.
/ LBA[LSB]
SC xx
VV
FR xx
At command completion (Shadow Block Registers contents to be read)
ST
Status information
DH
x x x x
xx
CH
CL
SN
SC
ER
CYL No. [MSB] / LBA
CYL No. [LSB] / LBA
SCT No.
/ LBA[LSB]
xx
Error information
•
SET MAX SET PASSWORD (Features Field = 01h)
This command requests a transfer of 1 sector of data from the host, and defines the
contents of SET MAX password. The password is retained by the device until the
next power cycle.
Summary of Contents for MHT2040BH
Page 1: ...C141 E203 01EN MHT2080BH MHT2060BH MHT2040BH DISK DRIVES PRODUCT MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 42: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 74: ...This page is intentionally left blank ...
Page 246: ...This page is intentionally left blank ...
Page 250: ...This page is intentionally left blank ...
Page 260: ...This page is intentionally left blank ...
Page 262: ...This page is intentionally left blank ...
Page 263: ......
Page 264: ......