C156-E097-01EN
4 - 17
(2)
If processing terminates abnormally:
a) If sense data has been obtained by the REQUEST SENSE command, analyze the sense data.
If the error is recoverable, retry the processing.
b) Check the following items for SCSI cable connection:
•
All connectors, including other SCSI devices, are connected correctly.
•
A terminating resistor is correctly mounted at both ends of the cable.
•
Power is supplied to the terminating resistors correctly.
c) Check the settings of all terminals are correct. Note that the procedure of checking the SCSI
connection depends on the setting of "spindle automatic stop".
4.7
Dismounting Drive
How to demount an optical disk drive (for setting terminal checking, setting change, or device
replacement) depends on the system cabinet configuration. Determine the demounting
procedure in consideration of the requirements of each system. This section describes the
general demounting procedure and notes on demounting drives.
Before demounting the optical disk drive, turn off the system power.
Do not remove screws securing the cables and drive when the power
is on.
1) Remove the power cable.
2) Remove the SCSI cable.
3) When an external operator panel is mounted, remove its cable. If it is difficult to access the
connector, remove the cable after step e).
4) Remove the DC ground cable.
5) Remove the four screws securing the drive, then remove the drive from the system cabinet.
6) When storing or transporting the drive, put the drive into an antistatic bag. (See Section 4.1.)
Summary of Contents for MCE3064SS
Page 1: ...C156 E097 01EN MCE3064SS MCF3064SS OPTICAL DISK DRIVES PRODUCT MANUAL ...
Page 3: ...This page is intentionally left blank ...
Page 31: ...This page is intentionally left blank ...
Page 52: ...C156 E097 01EN 2 21 Figure 2 3 Example of alternate processing ...
Page 53: ...This page is intentionally left blank ...
Page 72: ...C156 E097 01EN 3 19 Figure 3 17 SCSI cable connector ...
Page 81: ...This page is intentionally left blank ...
Page 97: ...4 16 C156 E097 01EN Figure 4 5 SCSI connection check 2 ...
Page 99: ...This page is intentionally left blank ...
Page 113: ...This page is intentinally left blank ...
Page 119: ...7 2 C156 E097 01EN Host system A Host system B Figure 7 1 Example of SCSI configuration ...
Page 133: ...7 16 C156 E097 01EN Figure 7 6 ARBITRATION phase ...
Page 135: ...7 18 C156 E097 01EN µ Figure 7 7 SELECTION phase 30 30 30 30 ...
Page 141: ...7 24 C156 E097 01EN Figure 7 10 Transfer in asynchronous mode 18 18 ...
Page 145: ...7 28 C156 E097 01EN Figure 7 11 Transfer in synchronous mode 11 11 11 11 43 18 43 18 ...
Page 146: ...C156 E097 01EN 7 29 Figure 7 12 Transfer in FAST SCSI mode ...
Page 148: ...C156 E097 01EN 7 31 Figure 7 13 Data transfer rate in asynchronous mode ...
Page 158: ...C156 E097 01EN 7 41 Figure 7 17 RESET condition ...
Page 160: ...C156 E097 01EN 7 43 Figure 7 18 Bus phase sequence 1 of 2 ...
Page 161: ...7 44 C156 E097 01EN Figure 7 18 Bus phase sequence 2 of 2 ...
Page 167: ...This page is intentionally left blank ...
Page 171: ...This page is intentionally left blank ...
Page 181: ......